4 VLAN configuration
Nortel Secure Router 8000 Series
Configuration - LAN Access and MAN Access
interface { ethernet | gigabitethernet }
interface-number.subinterface-number
The subinterface view appears.
Step 3 Run:
vlan-type dot1q
vlan-id
This command configures the encapsulation type and VLAN ID of the Ethernet subinterface.
By default, a subinterface is not encapsulated with 802.1Q and is not associated with any
VLAN. To maintain VLAN connectivity, the VLAN ID of the subinterface on two end hosts
must be the same.
—End
4.2.3 Configuring an IP address for the subinterface
A
When subinterfaces exist, if you use the shutdown command and the undo shutdown
command on the main interface in succession, use the two commands at an interval of at least
15 seconds.
Do as follows on the routers that belong to the VLANs that need to communicate:
Step 1 Run:
system-view
The system view appears.
Step 2 Run:
interface { ethernet | gigabitethernet }
interface-number.subinterface-number
This command creates the subinterface and displays the subinterface view.
Step 3 Run:
ip address
ip-address { mask
|
mask-length }
[
sub ]
This command configures the IP address of the subinterface.
—End
4.2.4 Checking the configuration
Run the following commands to check the previous configuration.
Action
Command
Check the VLAN packet
statistics for a subinterface.
display vlan statistics { vid vlan-id | interface
{ ethernet | gigabitethernet }
interface-numher.suhinterface-numher } *
4-8