beautypg.com

6 checking the configuration, 6 checking the configuration -7, Checking the configuration – Panasonic NN46240-502 User Manual

Page 26

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

background image

Nortel Secure Router 8000 Series

Configuration - LAN Access and MAN Access

1 LAN access overview

1.2.6 Checking the configuration

Run the following commands to check the previous configuration.

Action

Command

Check the interface running

status and statistics.

display interface [ interface-type [ interface-number ] ]

[ | { begin | exclude | include } regular-expression ]

Check brief IP information on

the interface.

display ip interface brief [ interface-type

[ interface-number ] ]

Run the display interface command. If the physical status, link layer protocol status, IP

address, mask, MAC address, and physical parameters of an interface are displayed, the

configuration is successful. For example:

display interface ethernet 2/0/0

Ethernet2/0/0 current state : UP

Line protocol current state : UP

Description : NORTEL, Nortel Series, Ethernet2/0/0 Interface

The Maximum Transmit Unit is 1500 bytes, Hold timer is 10(sec)

Internet Address is 100.1.3.1/24

IP Sending Frames’ Format is PKTFMT_ETHNT_2, Hardware address is 00e0-fc00-8fe1

Output queue : (Urgent queue : Size/Length/Discards) 0/50/0

Output queue : (Protocol queue : Size/Length/Discards) 0/1000/0

Output queue : (FIFO queue : Size/Length/Discards) 0/256/0

auto negotiation, speed 100M, duplex full, loopback not set

Last 300 seconds input rate 1111 bytes/sec, 1 packets/sec

Last 300 seconds output rate 349 bytes/sec, 0 packets/sec

Usage of input bandwidth:0.01%,Usage of output bandwidth:0.00%

Input: 1104 packets, 1134603 bytes

1 broadcasts, 1070 multicasts, 0 pauses

0 InvalidVlanPkts, 0 InvalidVlanOctets

0 errors, 0 shorts, 0 longs

0 physical errors, 0 input fragments

0 Jabbers, 0 CRCs, 0 overruns

Output: 402 packets, 362974 bytes

17 broadcasts, 368 multicasts

0 InvalidVlanPkts, 0 InvalidVlanOctets

0 shorts, 0 longs

0 runts, 0 Jabbers, 0 CRCs

0 deferrals, 0 underruns, 0 aborts

0 collisions, 0 lates, 0 singles, 0 multiples, 0 excessives

Run the display ip interface brief command. If the physical status, link layer protocol status,

IP address, loopback status, and description of an interface are displayed, the configuration is

successful. For example:

display ip interface brief gigabitethernet 1/0/0

*down: administratively down

(l): loopback

(s): spoofing

Interface

IP Address Physical Protocol Description

GigabitEthernet1/0/0 10.5.40.1 down down

Nortel

Issue 5.3 (30 March 2009)

Nortel Networks Inc.

1-7