4-2 SYSTEM INFORM ATION
1) SYSTEM EXCLUSIVE MESSAGE
O
1 MEMORY BULK DATA
The data received is the same as the data transmitted in “1
MEMORY
BULK
DATA,”
depciibed
in
the
‘Transmission
Data” section. Only programs 31 — 90 can be received.
o 1 BANK PROGRAM CHANGE ASSIGNMENT TABLE
BULK DATA
The data received is the same as the data transmitted in “1
BANK PROGRAM CHANGE ASSIGNMENT TABLE BULK
DATA,” described in the ‘Transmission Data” section.
© 60 MEMORY & ALL BANKS BULK DATA
The data received is the same as the data transmitted in “60
MEMORY & ALL BANKS BULK DATA,” described in the
“Transmission Data” section.
O PARAMETER CHANGE
The data received is the same as the data transmitted in “PA
RAMETER CHANGE,” described in the “Transmission Data”
section. When received, the specified parameters in the currently
selected program are changed.
© 1 MEMORY BULK DUMP REQUEST
When received, a bulk dump of the data contained in the speci
fied memory location is performed.
STATUS
I I I I 0000 (FOH)
ID NO.
0 I 0000 I I (4 3H)
SUB-STATUS
00 IOnnnn (2nH)
n =0 (channel no. 1 ) —
1 5 (channel no. 16)
FORMAT NO.
0 M I I I I 0 (7 EH)
HEADER
0 I 00 I I 00 (4CH)
"L”
0 I 00 I I 0 I (4DH)
"M"
00 I 00000 (2 OH)
space
00 I 00000 (2 OH)
space
00 I I I 000 (3 8H)
„ 8 ”
00 I I 00 I I (3 3H)
“3"
00 I I 0 I 00 (3 5H)
"5"
00 I I 0 I I 0 (36H)
"6"
DATA NAME
0 I 00 I I 0 I (4DH)
"M"
MEMORY NO.
Ommmmmmm
m =
1
(memory no. 1)
— 90 (memory no. 90)
EOX
I I I I 0 I I I (F7H)
© 1 BANK PROGRAM CHANGE ASSIGNMENT TABLE
BULK DUMP REQUEST
I
When received, a bulk dump of the data contained in the speci
fied program change assigment table is performed.
STATUS
1 1 1 1 0 0 0 0 (FOH)
ID NO.
0 1 0 0 0 0 1 1 (43H)
SUB-STATUS
O O l O n n n n (2nH)
n = 0 (channel no. 1)
— 1 5 (channel no. 16)
FORMAT NO.
0 1 1 1 1 1 1 0 (7EH)
HEADER
0 1 00 1 1 00 (4CH)
"L"
0 1 00 1 1 0 1 (4DH)
"M"
00 1 0 0 0 0 0 (2OH)
space
00 1 0 0 0 0 0 (20H)
space
00 1 1 1 000 (38H)
"8"
00 1 1 00 1 1 (3 3H)
"3"
00 1 1 0 100 (35H)
"5"
00 1 1 0 1 1 0 (36H)
"6"
DATA NAME
0 1 0 1 0 1 00 (54H)
"T"
BANK NO.
O b b b b b b b
b = 1 (bank A)
-4 (bank D)
EOX
1 1 1 1 0 1 1 1 (F7H)
17