Input attenuator adjustment – Yamaha DEQ7 User Manual
Page 15
Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".
* If the CONVERT function is executed while a program number
between 1 and 30 is selected, the CONVERT operation will be
canceled.
* When a program is converted using this function, the original
program is erased. If you wish to keep the original program.
make another copy of it in a RAM memory location using the
STORE function.
* User-edited titles are erased when programs are converted, and
are replaced with the appropriate preset title. Use the TITLE
EDIT function to create a new title if necessary.
INPUT ATTENUATOR ADJUSTMENT
I
This function makes it possible to independently adjust the input
attenuation (sensitivity) of the left and right channels when using
the DEQ7’s DIGITAL IN terminal. It is essential to set these para
meters properly to avoid “skipping” and digital noise that may
occur with high-level digital input signals. The INPUT ATTENU
ATOR control range is from 0 to 60 dB.
® Press the UTILITY key until the “INPUT ATTENUATOR
LEFT” function appears.
‘ Use the parameter editing A and V keys to set the required
amount of attenuation for the left channel.
Press the UTILITY key one more time to call the “INPUT
ATTENUATOR RIGHT” function.
® Use the parameter editing A and V keys to set the required
amount of attenuation for the right channel.
Hold the UTILITY key down until the UTILITY mode is ex
ited.
I N P U T A T T E N U A T E R
L E F T = + O d B
u
I N P U T A T T E N U A T E R
R I G H T S - t - O d B
13