SECT

IO

N

4

4-15

T-268-07

Table 4-2. Electrical Control Positions -- ABOVE --10_C (+14_F), or --5_C (+23_F) optionally

CONTROL CIRCUIT

COOLING

Holding Zone

* Dehumidification

HEATING

DEFROST

Single-Speed Compressor:
Compressor Contactor

(C)

Energized

De-energized

**

**

De-energized

1

Two-Speed Compressor in high speed mode:
Compressor Contactor

(CH)

Energized

De-energized

**

**

De-energized

1

Compressor Contactor

(CS)

Energized

De-energized

**

**

De-energized

1

Compressor Contactor

(CL)

De-energized

De-energized

**

**

De-energized

1

Two-Speed Compressor in low speed mode:
Compressor Contactor

(CH)

De-energized

De-energized

**

**

De-energized

1

Compressor Contactor

(CS)

De-energized

De-energized

**

**

De-energized

1

Compressor Contactor

(CL)

Energized

De-energized

**

**

De-energized

1

Condenser Fan

Contactor (CF)

Energized

De-energized

Energized

De-energized

De-energized

High Speed Evaporator

Contactor (EF)

Energized

Energized

Refer to section

3.1.7.a.2

Refer to

section

3.1.7.a.2

De-energized

2

Low Speed Evaporator

Contactor (ES)

De-energized

De-energized

Refer to section

3.1.7.a.2

Refer to

section

3.1.7.a.2

De-energized

Defrost Relay (TF)

De-energized

De-energized

De-energized

De-energized

Energized

Heater Relay (HR)

De-energized

De-energized

Energized

Energized

Energized

INDICATING LIGHTS

Cool

ON

OFF

ON

OFF

OFF

Defrost

OFF

OFF

OFF

OFF

ON

In-Range

On -- If In-Range (Refer to paragraph 3.1.4, Code 30)

Heat

OFF

OFF

ON

ON

ON

POWER CIRCUIT

Compressor

Energized

De-energized

Energized

De-energized

De-energized

Condenser Fan Motor

Energized

De-energized

Energized

De-energized

De-energized

Heaters

De-energized

De-energized

Energized

Energized

Energized

Evaporator Fan Motors

Energized

Energized

Energized

Energized

De-energized

* Unit with optional Humidity sensor

** Dehumidification and heating modes do not operate at set points below --10_C (14_F), or --5_C (23_F) optionally

1

-- May be energized in defrost if snap freeze portion of defrost is run.

2

-- May be energized in defrost if probe check portion of defrost is run.