SECTION 3

MICROPROCESSOR

3.1 MICRO-LINK 2i CONTROLLER MODULE

1

2

2

6

7

8

3

4

2

2

2

5

1. Micro-Link 2i Controller/DataCORDER Module

2. Connectors

3. Test Points

4. Fuses

5. Control Circuit Power Connection

(Location: In back of connector)

6. Battery Pack (Optional)

7. Software Programming Port

8. Mounting Screw

Figure 3-1. Micro-Link 2i Controller/DataCORDER Module

3.1.1

Brief Description

NOTE

Some units are equipped with an optional
emergency bypass switch (EB), which permits
manually

overriding

a

malfunctioning

Controller by locking the unit into a continuous

full cooling mode (see Figure 2-7).

WARNING

Do

not

attempt

to

service

the

Controller/DataCORDER

module.

Breaking the warranty seal will void the
warranty.

CAUTION

Remove

the

Controller/DataCORDER

module and unplug all wire harness

connectors before performing any arc
welding on any part of the container.

Do not remove wire harnesses from module
unless you are grounded to the unit frame

with a static safe wrist strap.

The

Carrier

Transicold

Micro-Link

2i

Controller/DataCORDER

is

a custom-designed

microprocessor-based module which incorporates
embedded software to:
a. Control supply or return air temperature to

extremely tight limits by providing modulated
refrigeration control, electric heat control and
defrost to ensure continuous conditioned air
delivery to the load.

b. Provide dual independent readouts of set point and

supply or return air temperatures.

c. Provide digital readout and ability to select data.

Refer to Table 3-3 for Controller Function Codes.
For Controller alarm digital display identification

refer to Table 3-4.

d. Provide a pre-trip step-by-step checkout of

refrigeration unit performance including: proper
component operation, electronic and refrigeration
control operation, heater operation, probe
calibration and current limiting. Refer to section
3.2.

e. Provide the ability to select or change Codes 27 to

37 and set point without AC power being hooked

up. Refer to section 3.1.4.