Carrier 69NT40-511-199 User Manual

Page 43

background image

SECT

IO

N

3

3-5

T-268-07

The display module (see Figure 3-2) is mounted at a 20
degree downward tilt to aid in visibility. The display

module consists of:
a. Two 25mm (1 inch) high, five digit LCD displays

which are easily viewed in direct sunlight and
backlighted for superior low-light visibility.

b. Seven Indicators:

S

Cool -- White Lamp: Energized when the
refrigerant compressor is energized.

S

Heat -- Orange LED: Energized when the
heaters are on, and the unit is in the heat or

defrost mode.

S

Defrost -- Orange LED: Energized when the
heaters are on, and the unit is in the defrost

mode.

S

In-Range -- Green LED: Energized when the

controlling temperature probe is in range.
(Supply air probe will be used for control in
the perishable ranges and the return air probe is
used for control in the frozen ranges.)

S

Alarm -- Red LED: Energized when there is
an active or an inactive shutdown alarm
(AL20 to AL27) in the alarm queue.

S

Supply -- Yellow LED: Energized when
supply temperature and set point are
displayed. Flashes if dehumidification or

humidification is enabled on units so
equipped.

S

Return -- Yellow LED: Energized when return
temperature and set point are displayed.

COOL

HEAT

DEFROST IN RANGE ALARM

SUPPLY

RETURN

SETPOINT/Code

AIR TEMPERATURE/Data

Figure 3-2. Display Module

NOTE

The default display mode will show the set
point temperature (on the left display) and
controlling probe temperature (on the right
display). The controlling probe in the

perishable range will be the SUPPLY air probe
and the controlling probe in the frozen range
will be the RETURN air probe.