beautypg.com

Carrier 69NT40-511-199 User Manual

Page 29

background image

2-10

T-268-07

2.2 REFRIGERATION SYSTEM DATA

Number of Cylinders

6

Model

06DR

CFM

41

Weight (Dry)

118 kg (260 lb) - Single-Speed

i. Compressor/Motor Assembly

Weight (Dry)

129.39 kg (285.25 lb) - Two-Speed

i. Compressor/Motor Assembly

Approved Oil

Castrol Icematic -- SW20

Oil Charge

3.6 liters (7.6 U.S. pints)

Oil Sight Glass

The oil level range, with the compressor off,

should be between the bottom and one-eighth

level of the capacity of the sight glass.

j. Expansion Valve Superheat

Verify at --18 _C

(0 _F) container box

temperature

4.48 to 6.67 _C (8 to 12 _F)

k Heater Termination Thermostat

Opens

54 (¦ 3) _C = 130 (¦ 5) _F

k. Heater Termination Thermostat

Closes

38 (¦ 4) _C = 100 (¦ 7) _F

l High Pressure Switch

Cutout

25 (¦ 1.0) kg/cm@ = 350 (¦ 10) psig

l. High Pressure Switch

Cut-In

18 (¦ 0.7) kg/cm@ = 250 (¦ 10) psig

Unit Configuration

Charge Requirements -- R-134a

Unit Configuration

2* row condenser

4* row condenser

m. Refrigerant Charge

Water-Cooled

Condenser

4.5 kg (9.0 lbs)

5.22 kg (11.5 lbs)

Receiver

3.74 kg (8.25 lbs)

4.88 kg (10.75 lbs)

* Refer to Table 1-1.

NOTE

When replacing the components (n.), (o.) and (p.) in section 2.2, refer to the installation instructions
included with the ordered new part for additional information.

n Fusible Plug

Melting point

99 _C = (210 _F)

n. Fusible Plug

Torque

6.2 to 6.9 mkg (45 to 50 ft-lbs)

o. Sight Glass/Moisture Indicator Torque

8.9 to 9.7 mkg (65 to 70 ft-lbs)

Bursts at

35 5% kg/cm@ = (500 5% psig)

p. Rupture Disc

Torque

(P/N 14-00215-03)

1.4 to 2 mkg (10 to 15 ft-lbs)

p. Rupture Disc

Torque

(P/N 14-00215-04)

6.2 to 6.9 mkg (45 to 50 ft-lbs)

q. Condenser Pressure

Condenser Fan Starts

The condenser fan will start if the condenser

pressure is greater than 14.06 kg/cm@ (200

psig) OR the condenser fan is OFF for more

than 60 seconds.

q. Condenser Pressure

Transducer (CPT)

Condenser Fan Stops

The condenser fan will stop if the condenser

pressure is less than 9.14 kg/cm@ (130 psig)

AND the condenser fan remains ON for at least

30 seconds.

r. Unit Weight

Refer to unit model number plate, see Figure 2-1 for location of plate.

s. Water Pressure Switch

Cut-In

0.5 ¦ 0.2 kg/cm@ (7 ¦ 3 psig)

s. Water Pressure Switch

(Optional)

Cutout

1.6 ¦ 0.4 kg/cm@ (22 ¦ 5 psig)

This manual is related to the following products: