Real Time Clock (RTC) Modification
S
Pre-Trip result & data
S
Trip Start
S
ISO Trip Header (Must be entered first via
Interrogation program)
S
Economy Mode Start
S
Economy Mode End
S
“Auto 2” Pre-Trip Start
S
“Auto 2” Pre-Trip End
S
Bulb Mode Start
S
Bulb Mode changes
S
Bulb Mode End
S
USDA Trip Comment
S
CTD Controlled Atmosphere Information
S
Humidification Start
S
Humidification End
S
USDA Probe Calibration
3.3.2
DataCORDER Configuration
NOTE
The DataCORDER software is integrated with
the Controller software.
Configuration to factory installed default configuration
is achieved via a common configuration card used for
controller functions, see section 3.1.2.
Changes to the factory default configuration must be
made with the Interrogation device.
Configuration:
Tells the operational software what physical
components are built into the container unit, how many
sensors to record, what recording interval should be
used, etc..
ITEM
SETTING
FACTORY
DEFAULT
Sensor Logging
(Network)
Average or
Snapshot
Average
Sensor Logging
(Thermistor)
Average,
Snapshot or
USDA
Average
Sensor Format
1 or 2 byte
1 byte
Sensor
Configuration
Refer to section
3.3.5.f.
2 sensors
Logging Interval
15, 30, 60 or
120 minutes
60 minutes
Configuration cards are available thru CTD
Replacement Components Group.
The use of a programming card in the field should only
occur under unusual circumstances, such as a physical
component in the container unit is changed to a different
component, resulting in a new configuration for the
unit.