beautypg.com

Waterworks Universal Two Way Diverter Valve with Shutoff for Thermostatic Shower Systems User Manual

Installation guidelines

background image


PRODUCT SUPPORT 800.927.2120 8am - 6pm EST

UNIVERSAL
Two Way Diverter with Shutoff Valve

Installation Guidelines

Page 1 of 2

Rev - 04


6.16.2014

These guidelines have been prepared for the professional contractor to aid in the installation of:
UNIVERSAL TWO WAY DIVERTER WITH SHUTOFF VALVE
STYLE No. GUDV14, GU14DV (UK).
All dimensions are based on original specification and are subject to change and variation.
Please consult your Design Associate for current specifications.

STYLE No. GUDV14†
CODE No. GUSV14R

SPECIFICATIONS:

Fitting Hole Diameter

Ш2 1/2" * (Ш 63.5mm)

Inlet Connection Size &
Type:

3/4" Female NPT†

Outlet Connection Size &
Type:

1/2" Female NPT†

Recommended Water
Pressure:

45 psi (3 Bar)

Unrestricted Maximum
Flow Rate:

14 gpm @ 45 psi
(53 L/min @ 3 Bar)

Valve Material:

Ceramic

Water Pressure:

20 psi MIN - 80psi MAX
(1.4 Bar Min - 5.5 Bar Max)

* Ø2 1/2" hole is required for servicing the valve


† UK Style No. GU14DV supplied with 3 BSP Adapters,
assembly required.

REQUIRED PLUMBING DETAILS:

Universal Two Way Thermostatic Diverter Valve Trim

STYLE No. UNDV2T

Universal Thermostatic Valve

STYLE No. GUTH37 or,

Universal 1/2" Thermostatic Valve

STYLE No. GUTH56 or,

.25 Thermostatic Valve

STYLE No. GUTH78


IMPORTANT:

¾ To ensure this product is installed properly, you must

read and follow these guidelines.


¾ The owner/user of this product must keep this

information for future reference.


¾ This product can only be used with either the Universal

Thermostatic Valve (GUTH37), the Universal 1/2"
Thermostatic Valve (GUTH56) or the .25 Thermostatic
Valve (GUTH78).

¾ This valve requires a compatible wall valve trim and

trim plate. ALL PRODUCTS SOLD SEPARATELY.

¾ This product, the thermostatic valve (GUTH37,

GUTH56 or GUTH78) and the associated trims must be
on-site prior to rough-in. This allows the installer to
visualize the installation.

¾ Inspect this product to assure you have all the parts

required for proper installation.

¾ Refer to the specification and assembly drawings

attached. Product is sold partially assembled but
shown fully disassembled for illustrative and service
purposes only.

¾ This product must be installed by a professional

licensed contractor. Be sure your installation conforms
to all federal, state, and local codes. In the State of
Massachusetts, all installations must comply with the
rules and regulations set forth within 248 CMR.

¾ Check incoming water pressure.

FUNCTION:

¾ The Thermostatic Valves (GUTH37, GUTH56 and

GUTH78) only mix hot and cold water, they do not
have an on/off or volume control function. Mixed
water flows out at a fixed volume to the diverter valve
(GUDV14) which has 3 positions:

2 that can direct water flow to a maximum of 2
devices. Water cannot flow out of the devices
simultaneously (i.e. out of the shower head AND
handshower together).

1 position that shuts the water off to all devices.

ROUGH-IN:

¾ Valve rough-in depth is measured from the centerline

of the inlets to the surface of the finished wall and
varies depending on the trim and thermostatic valve
being used.

GUDV14 with GUTH37 Rough-In Depth:

Trim Rough-In

Depth

.25, Flyte,
Opus &
R.W. Atlas

3 1/8" MIN - 4-1/8" MAX

(79mm MIN - 104mm MAX)

Formwork

3 1/8" MIN - 4 3/4" MAX

(79mm MIN - 121mm MAX)

Henry

2 7/8" MIN - 4 1/8" MAX

(73mm MIN - 104mm MAX)

All Other

2 1/2" MIN - 4 1/8" MAX

(64mm MIN - 104mm MAX)


GUDV14 with GUTH56 Rough-In Depth:

All Other

3 1/4" MIN - 4 1/4" MAX

(83mm MIN - 108mm MAX)


GUDV14 with GUTH78 Rough-In Depth:

All Other

3 1/8" MIN - 4 1/8" MAX

(79mm MIN - 104mm MAX)