These guidelines have been prepared for the professional contractor to aid in the installation of:
HENRY THERMOSTATIC VALVE STYLE NO. GUTH47, GU47TH (UK)
All dimensions are based on original specification and are subject to change and variation.
Please consult your Design Associate for current specifications.
¾ See Figure - 03 for steps 3-6.
3. Run 3/4" (22mm) copper supply lines to the proper
height of the valve inlets and be sure to secure all
piping and fittings.
4. This valve includes VOLUME CONTROLS or ON/OFF
VALVES to control each fitting that will have water
flowing to it.
5. Install the TILE GUARD to protect the valve during
the completion of the finished wall and to create the
exact opening for access to the service stops and
future servicing.
3/4" (22mm)
COLD SUPPLY
OUTLET TO
SHOWER
FITTING
VOLUME CONTROL
ON/OFF VALVE
THERMOSTATIC VALVE
(FLUSH PLATE
PRE-INSTALLED)
3/4" (22mm)
HOT SUPPLY
VOLUME CONTROL
ON/OFF VALVE
OUTLET TO
SHOWER
FITTING
TILE
GUARD
3/4" (22mm)
COLD SUPPLY
OUTLET TO
SHOWER
FITTING
VOLUME CONTROL
ON/OFF VALVE
THERMOSTATIC VALVE
(FLUSH PLATE
PRE-INSTALLED)
3/4" (22mm)
HOT SUPPLY
VOLUME CONTROL
ON/OFF VALVE
OUTLET TO
SHOWER
FITTING
TILE
GUARD
FIGURE - 03
FLUSH OUT THE SYSTEM:
¾ Before installing the cartridge, the supply lines must
be flushed out to prevent clogging of the filter
screens. Failure to flush the lines will permanently
damage the cartridge and void the warranty. Repeat
this process as needed prior to trim installation.
¾ See Figure - 04 for steps 6-10.
6. The VALVE BODY is shipped with the FLUSH PLATE
pre-installed, and is ready for flushing the lines.
7. Turn on the water supply and open the SERVICE
STOPS to flush out the lines then inspect all
connections for leaks.
8. After the lines are flushed, turn off the water supply
and close the SERVICE STOPS, unthread the 2 cover
SCREWS, then remove the FLUSH PLATE.
9. Install the CARTRIDGE using the 2 cover SCREWS
and turn off the SERVICE STOPS.
ROUGH-IN:
1.
Make sure the valve body is positioned according to
valve markings so the inlets are situated with hot
piped on the left and cold piped on the right. See
Figure - 01.
VOLUME CONTROL
ON/OFF
VOLUME CONTROL
ON/OFF
FLUSH PLATE
PRE-INSTALLED
VOLUME CONTROL
ON/OFF
VOLUME CONTROL
ON/OFF
FLUSH PLATE
PRE-INSTALLED
H
C
5-11/16"
(144.5mm)
CENTER
OF INLETS
5-11/16"
(144.5mm)
13/16"
(21mm)
OUTLET
TO SHOWER
FITTING
OUTLET
TO SHOWER
FITTING
FIGURE - 01
2. IMPORTANT: Valve rough-in depth is measured
from the center of the inlets to the surface of the
finished wall and varies depending on the trim used.
See Figure - 02
FINISHED
WALL
FLUSH PLATE
PRE-INSTALLED
FINISHED
WALL
FLUSH PLATE
PRE-INSTALLED
CENTER
OF INLETS
ROUGH-IN DEPTH
2-1/8" MIN - 3-1/8" MAX
(54mm MIN - 79mm MAX)
FIGURE - 02