Waterworks Julia Exposed Tub Filler with Handshower and Metal Lever Diverter User Manual
Installation guidelines
These guidelines have been prepared for the professional contractor to aid in the installation of:
JULIA EXPOSED DECK MOUNTED TUB FILLER WITH HANDSHOWER AND
CROSS HANDLES (JUTU01, JUTU02-K, JUTU03-K & JUTU07)
All dimensions are based on original specification and are subject to change and variation. Please
consult your Design Associate for current specifications.
Installation Guidelines
W A T E R W O R K S
Waterworks is a registered trademark of Waterworks Inc.
10.09.06
4
3
4
"
8
7
8
"
5
7
8
"±
3
4
"
2
3
8
"Ø
6
7
8
"±0"
3
3
4
"
3
1
4
"
JUTU01(white porcelain diverter and handshower)
JUTU02-K(metal diverter and handshower-MTO)
JUTU03-K(black porcelain and handshower-MTO)
JUTU07(deck unions)
Julia Exposed Deck Mounted Tub Filler With Handshower And Cross
Handles
IMPORTANT
To ensure this product is installed properly, you
must read and follow these guidelines.
The owner/user of the tub filler must keep this
information for future reference.
Be sure your installation conforms to local codes.
Anti scald protection is the responsibility of the
installer and according to applicable codes.
This tub filler should be on-site prior to rough in
and allows the installer to visualize the installation
and verify the center spread.
An access panel must be installed for servicing and
installation.
Check tub deck and tub measurements to assure
the spout projects far enough into the tub.
Refer to the specification and assembly drawings
attached. Tub filler is sold partially assembled but
shown fully disassembled for illustrative and service
purposes only.
Inspect this product to assure you have all parts
required for proper installation.
Use only a strap wrench or protected/smooth-jaw
wrench on any finished surface.
Install accessible hot and cold service stop valves to
facilitate servicing.
Do NOT use putty during this installation. Upper
and lower washers are provided.
ROUGH IN:
IMPORTANT: Check tub deck and tub measurements
to assure the spout projects far enough into the
tub.
1. Run well supported
1
2
" hot and cold supply lines.
The spread between supplies is 5
7
8
". 1
3
8
" drilling for
the mounting holes is recommended.
TUB FILLER INSTALLATION:
2. Unthread and remove the
1
2
" Straight female x
1
2
"
NPT male adapter (17,16c), both washers (16,16a),
the mounting nut (16b) from the deck union
(15-15d).
3. Insert the union into the deck and re-install the
mounting gaskets then nut onto the union.
4. Apply pipe thread compound to the union, insert
the
1
2
" washer (16c) into the adapter (17) then
thread the adapter onto the union.
5. Apply pipe thread compound onto the male end of
the adapter then thread it into a
1
2
" female IPS x
sweat adapter
6. Adjust the supply line lengths as needed and
complete final connections.
7. Tighten the mounting nut up against the underside
of the deck.
8. Install a washer into each inlet (6a) then attach the
tub filler to the deck unions by tightening the nuts
on the back side of the tub filler.