Installation guidelines
Opus Egg Cr ystal Handle Wall Valve And Trim
11/02
W A T E R W O R K S
These guidelines have been prepared for the professional contractor to aid in the installation of:
OPUS EGG CRYSTAL HANDLE WALL VALVE AND TRIM
(GUSV12R & OPSV48)
All dimensions are based on original specifications and are subject to change and variation.
Please consult your Design Associate for current specifications.
Installation Guidelines
1
NOTES:
➢
Use only a protected, smooth-jawed, or strap wrench on any finished
surface.
ROUGH-IN:
➢
Install the valve in the wall at the recommended depth. Ensure the valve
is installed with the water flowing in the direction indicated.The valve
should be installed at a height and spread (if applicable) comfortable to
the user.
➢
Separate service stops downstream will facilitate the servicing of the
control valve.The stops need to be installed in an accessible location.
FINISH:
➢
Screw the handle trim and connector together.Then thread the trim
assembly onto the valve until fully seated.
➢
Measure from the base of the escutcheon to the wall. Remove the trim
assembly and retain this measurement.
➢
Cut the valve stem and threaded sleeve so that the trim becomes flush
with the finished wall.The amount cut from the valve stem and threaded
sleeve should be the same as the distance measured in the previous step.
➢
Slide the valve stem extension and handle fixing cap over the valve stem.
Thread the handle trim assembly onto the threaded sleeve. Push handle
to lock onto the fixing cap.
➢
Check to ensure the escutcheon is flush to the finished wall. If necessary,
cut the valve stem and threaded sleeve further to make flush.
➢
Carefully turn on the water supply and check all connections for leaks.
➢
If further assistance is required, please contact Product Support at
1-800-927-2120 (8am-7pm EST).
ø 2
5
⁄
8
"
2
3
⁄
4
" min.
4
1
⁄
2
" max.
3
1
⁄
8
"
Note:
• Ideal Operating Pressure is 40-50 psi
• Maximum Static Pressure is 125 psi
• Minimum Pressure is 25 psi
3
⁄
4
" Female NPT
GUSV12R (rough) & OPSV48 (trim)
Valve Stem Extension
Valve
Handle Trim Connector
Escutcheon
Handle
Handle Fixing Cap
Figure 1
8.15.07
OPSV38 (trim)
OPSV38