Waterworks Julia Pressure Balance Control Valve Trim with White Porcelain Lever Handles User Manual
Installation guidelines, Julia pressure balance valve trim
Installation Guidelines
W A T E R W O R K S
Waterworks is a registered trademark of Waterworks Inc.
10.09.06
Shower Outlet
Tub Outlet
Julia Pressure Balance Valve Trim
IMPORTANT
To ensure this product is installed properly, you must
read and follow these guidelines.
The owner/user of the valve must keep this
information for future reference.
The risk of scalding exists until the installer has
properly set the temperature high limit stop.
This product must be installed by a professional
contractor and conform to all applicable codes
Refer to the specification and assembly drawings
attached. Valves are sold partially assembled but
shown fully disassembled for illustrative and service
purposes only.
If soldering any connections, remove diverter
assembly and cartridge to prevent damage to seals.
This valve should be on-site prior to rough in and
allows the installer to visualize the installation.
Inspect this product to assure you have all parts
required for proper installation.
Check incoming water pressure; ideal operating
pressure is 40-50 psi. The minimum is 25 psi. and the
maximum is 80 psi.
Use only a strap wrench or protected/smooth-jaw
wrench on any finished surface.
ROUGH IN: (GUSV81R ROUGH SOLD
SEPARATELY):
IMPORTANT - remove cartridge (11-13) when
soldering any connections. Failure to remove the
cartridge will damage both assemblies.
1. Install rough piping and valve body as shown.
-Refer to marking on valve body when installing. When
facing valve, HOT 'H" is on the left and COLD 'C' is
on the right.
-Valve should be installed with the plastic tile guard
lettering face flush with the finished wall.
2. Tile finished surface of wall, be careful to keep all ports
free of obstructions.
3. Turn on the hot and cold supplies and flush out the
valve.
-Valve will not operate unless both hot and cold water
are turned on.
-Allow valve to run in warm position for a few minutes
to totally flush the system.
IF SYSTEM IS EXCESSIVELY DIRTY, REMOVE THE
CONTROL STEM ASSEMBLY TO ENSURE PROPER
FLUSHING.
4. Tighten packing nut (10) for desired rotational
resistance in handle.
VALVE OPERATION:
5. When the finished wall is complete, open the hot and
cold supplies. The supplies are opened by removing
the service stop cap (26) and stop retainer (25) then
turning the
3
16
" hex screw (22) counter clockwise.
Both supplies must be on or the valve will not
operate.
6. Pull off the tile shield and discard.
7. The handle is for controlling temperature only, not
volume. Install the handle (1-1f) so it rests at 6
o-clock in the OFF position then turn the handle
counter clockwise through the cold position then
warm and stopping at the hot position. If additional
rotational friction is required to maintain the handle
position, tighten the packing nut (10).
Surface of finished
wall
JUSV31-K (metal lever handle trim) & GUSV81R (rough)
JUSV32-K (white porcelain lever handle trim) & GUSV81R (rough)
JUSV33-K (black porcelain lever handle trim-MTO) & GUSV81R (rough)
3
1
2
"
2
3
8
"±
1
2
"
JUSV32-K, 33-K
3
5
8
"
5
7
8
"
These guidelines have been prepared for the professional contractor to aid in the installation of:
JULIA PRESSURE BALANCE VALVE TRIM (JUSV31-K, JUSV32-K, JUSV33-K
& GUSV81R) All dimensions are based on original specification and are subject to change and variation.
Please consult your Design Associate for current specifications.