These guidelines have been prepared for the professional contractor to aid in the installation of:
FORMWORK DIVERTER TRIM PLATES for THERMOSTATIC SYSTEMS (STYLE# SEE ABOVE) All
dimensions are based on original specification and are subject to change and variation.
Please consult your Design Associate for current specifications.

Style No. FM2T01

2 Way Diverter Trim Plate for
Thermo with Metal Knob
Handle

Style No. FM2T10

2 Way Diverter Trim Plate for
Thermo with Metal Lever
Handle

SPECIFICATIONS:
Control Valve Rough-in Depth Minimum: 3-1/8"
Control Valve Rough-in Depth Maximum: 4-3/4"

REQUIRED PLUMBING DETAILS:
Universal Two Way Diverter without Shutoff Valve
STYLE # GUDV14 (SOLD SEPARATELY)

Style No. FM3T01

3 Way Diverter Trim Plate for
Thermo with Metal Knob
Handle

Style No. FM3T10

3 Way Diverter Trim Plate for
Thermo with Metal Lever
Handle

SPECIFICATIONS:
Control Valve Rough-in Depth Minimum: 3-1/8"
Control Valve Rough-in Depth Maximum: 4-3/4"

REQUIRED PLUMBING DETAILS:
Universal Three Way Diverter without Shutoff Valve
STYLE # GUDV66 (SOLD SEPARATELY)

IMPORTANT:

¾ To ensure this product is installed properly, you

must read and follow these guidelines. The
owner/user of this product must keep this
information for future reference.

¾ This product must be installed with a Two or Three

Way Diverter Valve (SOLD SEPARATELY). Please
refer to the specific valve installation guidelines for
rough-in requirements.

¾

Be sure your installation conforms to federal state,
and local codes. In the State of Massachusetts, all
installations must comply with the rules and
regulations set forth within 248 CMR.

¾ This product must be installed by a professional

licensed contractor and must be onsite prior to
rough-in, this allows the installer to visualize the
installation.

¾ Inspect this product to ensure you have all the parts

required for proper installation.

¾ Use only a strap wrench or protected/smooth-jaw

wrench on any finished surface.

¾ The use of certain plumber's putty may stain stone

or tile surfaces.

DIVERTER VALVE INSTALLATION:

Dimension Value

(inches)

A 3/16"
B 3/16"

CARTRIDGE

STEM

THREADED

TUBE

CARTRIDGE

STEM

THREADED

TUBE

"A"

CUT CARTRIDGE STEM

IN FRONT OF THE

FINISHED WALL

"B"

CUT THREADED TUBE

BEHIND FINISHED WALL

ROUGH -IN DEPTH

FIGURE - 01

*Warning: If Valve is roughed in too shallow, trim cannot
be installed correctly.