Installation guidelines – Waterworks Henry One Hole Bar Faucet , Metal Cross Handle User Manual
Page 2
PRODUCT SUPPORT 800.927.2120 8am - 6pm EST
HENRY
One Hole Bar Faucet with Metal Cross Handle
Installation Guidelines
Page 2 of 2
Rev - 01
10.16.2014
These guidelines have been prepared for the professional contractor to aid in the installation of:
HENRY ONE HOLE BAR FAUCET WITH METAL CROSS HANDLE (STYLE No. HNKM40, HN40KM UK).
All dimensions are based on original specification and are subject to change and variation.
Please consult your Design Associate for current specifications.
3. Re-install the LOWER RUBBER WASHER, METAL
WASHER and NUTS. Securely tighten the NUTS to
secure the SPOUT ASSEMBLY to mounting surface.
4. Connect the HOSES to the water supplies making sure
they are not pinched or kinked.
OPTIONAL HOT LIMIT SAFETY STOP CALIBRATION:
¾ Refer to FIGURE – 02a & FIGURE - 2b for steps 5 - 8.
5. Remove the HANDLE ASSEMBLY by unthreading the
HANDLE BASE from the SPOUT BODY.
6. Loosen the ADJUSTMENT SCREWS to allow the LIMIT
STOP PLATES to rotate freely. The orientation of LIMIT
STOP COLLAR can also be adjusted.
7. Place the HANDLE ASSEMBLY over cartridge stem
and beginning in the off position rotate handle
counterclockwise towards full hot. Using a
thermometer measure the water temperature and
adjust the handle until the desired temperature is
reached. The LIMIT STOP PIN makes contact with the
LIMIT STOP PLATE and will move it.
8. Remove the HANDLE ASSEMBLY and tighten the
ADJUSTMENT SCREWS to set hot temperature limit.
Re-attached HANDLE ASSEMBLY to SPOUT
ASSEMBLY to complete calibration.
LIMIT
STOP
PLATES
ADJUSTMENT
SCREWS
LIMIT
STOP
COLLAR
HANDLE
BASE
HOT
TEMPERATURE
LIMIT STOP
HANDLE
ASSEMBLY
LIMIT
STOP
PLATES
ADJUSTMENT
SCREWS
LIMIT
STOP
COLLAR
HANDLE
BASE
HOT
TEMPERATURE
LIMIT STOP
HANDLE
ASSEMBLY
FIGURE - 02a
LIMIT
STOP
PIN
LIMIT
STOP
PIN
FIGURE - 02b
FINISH AND INSPECT THE INSTALLATION:
9. Remove the FLOW RESTRICTING AERATOR from the
SPOUT ASSEMBLY using the AERATOR REMOVAL
KEY, then open the hot and cold supplies and carefully
turn the HANDLE to flush out any debris in the supply
lines.
10. Inspect all connections for leaks.
11. Shut the water off and re-install the FLOW
RESTRICTING AERATOR.
SERVICING THE CARTRIDGE:
¾ Refer to FIGURE – 03 for step 12.
12. To access the CARTRIDGE, remove the HANDLE
ASSEMBLY by unthreading the HANDLE BASE then
unthread the RETAINING COLLAR to expose the
CARTRIDGE.
SPOUT
ASSEMBLY
CARTRIDGE
RETAINING
NUT
HOT
TEMPERATURE
LIMIT STOP
HANDLE
BASE
HANDLE
ASSEMBLY
SPOUT
ASSEMBLY
CARTRIDGE
RETAINING
NUT
HOT
TEMPERATURE
LIMIT STOP
HANDLE
BASE
HANDLE
ASSEMBLY
FIGURE - 03
¾ If further assistance is required, please contact Product
Support at 1-800-927-2120 Ext 2 Monday through
Friday, 8am - 6pm EST.
¾ See the service part document for parts ordering,
available on WATERWORKS.COM.
* Putty contains oil and can cause permanent
discoloration on certain materials such as marble,
granite and any porous surface.