beautypg.com

Installation guidelines – Waterworks Henry One Hole Bar Faucet , Metal Cross Handle User Manual

Page 2

background image


PRODUCT SUPPORT 800.927.2120 8am - 6pm EST

HENRY
One Hole Bar Faucet with Metal Cross Handle

Installation Guidelines

Page 2 of 2

Rev - 01


10.16.2014

These guidelines have been prepared for the professional contractor to aid in the installation of:
HENRY ONE HOLE BAR FAUCET WITH METAL CROSS HANDLE (STYLE No. HNKM40, HN40KM UK).
All dimensions are based on original specification and are subject to change and variation.
Please consult your Design Associate for current specifications.

3. Re-install the LOWER RUBBER WASHER, METAL

WASHER and NUTS. Securely tighten the NUTS to
secure the SPOUT ASSEMBLY to mounting surface.

4. Connect the HOSES to the water supplies making sure

they are not pinched or kinked.


OPTIONAL HOT LIMIT SAFETY STOP CALIBRATION:

¾ Refer to FIGURE – 02a & FIGURE - 2b for steps 5 - 8.

5. Remove the HANDLE ASSEMBLY by unthreading the

HANDLE BASE from the SPOUT BODY.

6. Loosen the ADJUSTMENT SCREWS to allow the LIMIT

STOP PLATES to rotate freely. The orientation of LIMIT
STOP COLLAR can also be adjusted.

7. Place the HANDLE ASSEMBLY over cartridge stem

and beginning in the off position rotate handle
counterclockwise towards full hot. Using a
thermometer measure the water temperature and
adjust the handle until the desired temperature is
reached. The LIMIT STOP PIN makes contact with the
LIMIT STOP PLATE and will move it.

8. Remove the HANDLE ASSEMBLY and tighten the

ADJUSTMENT SCREWS to set hot temperature limit.
Re-attached HANDLE ASSEMBLY to SPOUT
ASSEMBLY to complete calibration.

LIMIT

STOP

PLATES

ADJUSTMENT

SCREWS

LIMIT

STOP

COLLAR

HANDLE

BASE

HOT

TEMPERATURE

LIMIT STOP

HANDLE

ASSEMBLY

LIMIT

STOP

PLATES

ADJUSTMENT

SCREWS

LIMIT

STOP

COLLAR

HANDLE

BASE

HOT

TEMPERATURE

LIMIT STOP

HANDLE

ASSEMBLY

FIGURE - 02a

LIMIT

STOP

PIN

LIMIT

STOP

PIN

FIGURE - 02b

FINISH AND INSPECT THE INSTALLATION:

9. Remove the FLOW RESTRICTING AERATOR from the

SPOUT ASSEMBLY using the AERATOR REMOVAL
KEY, then open the hot and cold supplies and carefully
turn the HANDLE to flush out any debris in the supply
lines.

10. Inspect all connections for leaks.

11. Shut the water off and re-install the FLOW

RESTRICTING AERATOR.


SERVICING THE CARTRIDGE:

¾ Refer to FIGURE – 03 for step 12.

12. To access the CARTRIDGE, remove the HANDLE

ASSEMBLY by unthreading the HANDLE BASE then
unthread the RETAINING COLLAR to expose the
CARTRIDGE.

SPOUT

ASSEMBLY

CARTRIDGE

RETAINING

NUT

HOT

TEMPERATURE

LIMIT STOP

HANDLE

BASE

HANDLE

ASSEMBLY

SPOUT

ASSEMBLY

CARTRIDGE

RETAINING

NUT

HOT

TEMPERATURE

LIMIT STOP

HANDLE

BASE

HANDLE

ASSEMBLY

FIGURE - 03

¾ If further assistance is required, please contact Product

Support at 1-800-927-2120 Ext 2 Monday through
Friday, 8am - 6pm EST.

¾ See the service part document for parts ordering,

available on WATERWORKS.COM.


* Putty contains oil and can cause permanent

discoloration on certain materials such as marble,
granite and any porous surface.