These guidelines have been prepared for the professional contractor to aid in the installation of:
JULIA TWO HOLE BRIDGE ARTICULATED KITCHEN FAUCET WITH METAL CROSS HANDLES AND SPRAY
(STYLE No. JUKM42), JULIA TWO HOLE BRIDGE ARTICULATED KITCHEN FAUCET WITH METAL LEVER
HANDLE AND SPRAY (STYLE No. JUKM43).
All dimensions are based on original specification and are subject to change and variation.
Please consult your Design Associate for current specifications.

FINISH AND INSPECT INSTALLATION:

15. Connect the SPOUT and VALVE to the water supplies

using the SUPPLY NUTS provided.

NOTE: This product does not have an integrated
diverter. Water cannot be diverted from the SPOUT to
the SPRAY. The SPRAY requires its own water supply.

16. Unthread the AERATOR HOUSING and remove the

AERATOR from the SPOUT, then open the inlet
supplies and carefully turn both HANDLES on the
SPOUT to flush out any debris in the supply lines.


17. Inspect all connections for leaks then re-install the

AERATOR, making sure to include the O-RING.


18. Unthread the HOSE from the SPRAY, then open the

inlet supply and carefully turn the HANDLE to flush out
any debris in the supply line.

19. Inspect all connections for leaks then thread the HOSE

back onto the SPRAY and place the SPRAY back into
the SHANK.


SERVICING THE SHUT-OFF CARTRIDGE(S):

Refer to FIGURE – 04 for Steps 1 through 2.

FIGURE - 04

1. Pull off the INDICE ASSEMBLY to expose the HANDLE

SCREW. The INDICE ASSEMBLY will come off as one
piece. It is held in place by an O-RING.

2. Unthread the HANDLE SCREW, pull off the HANDLE

and unthread the GLAND COVER to expose the
cartridge.

RUBBER

PAD

INDICE

RETAINING

COLLAR

POST

O-RING

GLAND COVER

HANDLE

HANDLE SCREW

RUBBER

PAD

INDICE

RETAINING

COLLAR

POST

O-RING

GLAND COVER

HANDLE

HANDLE SCREW

If further assistance is required, please contact Product

Support at 1-800-927-2120 Ext 2 Monday through
Friday, 8am - 6pm EST.

* Putty contains oil and can cause permanent

discoloration on certain materials such as marble,