3 display message command format (matrix display), Display message command format (matrix display) – Rice Lake SURVIVOR LaserLight Series Stop/Go Remote Displays - Installation & Operation Manual User Manual
Page 26

22
LaserLight Installation and Operation Manual
3.7.3
Display Message Command Format (Matrix Display):
3m8 and 3m12 remotes.
|
where:
| = Pipe character (0x7C)
AA = Two byte address, ASCII digits
DM = Two byte command, ASCII characters
| = Pipe character (0x7C)
timeout. Anything above that number indicates an indefinite display.
| = Pipe character (0x7C)
| = Pipe character (0x7C)
| = Pipe character (0x7C)
| = Pipe character (0x7C)
| = Pipe character (0x7C)
= Text to display
! = Exclamation point character (0 x 21)
Examples:
Scroll the message “Rice Lake Weighing Systems” 2 times
|00DM|0|N|N|Y|2|Rice Lake Weighing Systems!
Slide on and flash the message “DRIVE AHEAD” for 5 seconds
|00DM|5000|Y|Y|N|0|DRIVE AHEAD!
Command
Description
DM
is the 6 character message to display. If less than 6 characters, send spaces so it equates to 6
characters. Otherwise, some data may not be overwritten.
Example: |00DMSTOP !
GT
Get time and date. Information gathered is sent back to the indicator so that both the remote display and
indicator match. This is not displayed on the remote display.
Example: |00GT!
ST
Set time and date. Note that two spaces are required between time and date entries.
Example: |ST08:00:00 2003-01-31!
DI
Get digital input state
DO
Get digital output state
GR
Get relay state. Relay 0-3, 0=Off=LL, state 1=LH, state 2=HL, state 3=On=HH.
SR
Set relay state (output relays only). Relay 0-1, state 1=On & 0=Off.
GB
Get the number of 5 x 7 Max6953 boards (0 = 7-seg, 2, 3 = 5 x 7)
GV
Get the version number
DC
Dump configuration parameters (for testing purposes only)
TP
Temperature adjustment. Allows +/- 5% degree adjustment
Time and date is sent from the remote display depending on the current remote display time and date format:
Time and date are sent to the remote display in ISO format.
USA Format: HH:MM:SS AM/PM MMM/DD/YYYY
ISO Format: HH:MM:SS YYYY-MM-DD
If the real time clock is disabled in the remote display, an error message is sent back.