Configuration
15
Serial Menu
Parameter
Choices
Description
Level 2 Submenus
Port 0
BAUD
PARITY
DATA BITS
STOP BITS
HOLD WT
LOCK
E CHAR
LW POS
LENGTH
PRIM U
SEC U
GROS C
NET C
MOTION
SP IND
Configure Port 0. See Level 3 submenu parameter descriptions.
Keeps last weight displayed if communication is lost and prevents the remote
display from going into an error condition.
If enabled, prevents the Auto-Learn (Section 3.1) parameter from working
and ensures settings remain currently set.
This feature looks at the last character to determine the end of a packet.
Can select a number between 5 and 50. Is zero indexed and determines last
weight position of the format.
Can select a number between 5 and 75 and determines the length of packet
in the string format.
Select primary unit characters
Select secondary unit characters
Select gross character
Select net character
Select motion status character
Select, decode status, and settings for special indicator type.
0 = none
1 = Toledo 8142 format
PORT 1
BAUD
PARITY
DATA BITS
STOP BITS
ECHO
LOCK
Configure Port 1. See level 3 submenu parameter descriptions.
Disable this to allow echoing between remote display and other devices. Data
settings should be set equal to or greater than device being echoed to.
If disabled, remote display uses same settings as indicator after an
Auto-Learn.
Table 3-4. Serial Communication Menu Summary
Serial Menu
Port 0
Parameter
Choices
Description
Level 3 Submenus
7-Segment
Display
Parameters
8-Character
Display
Parameters
12-Character
Display
Parameters
BAUD
BAUD
BAUD
1200
2400
4800
9600
19200
Baud rate. Selects the transmission speed for Port 0
PARITY
PARITY
PARITY
ODD
EVEN
NONE
Selects the parity of data of Port 0
DATA DATABITS
DATA
BITS
7
8
Selects the number of data bits of Port 0
Table 3-5. Port 0 Serial Menu
If selected, the
appropriate
annunciator is lit