1 ac wiring, Ac wiring – Rice Lake SURVIVOR LaserLight Series Stop/Go Remote Displays - Installation & Operation Manual User Manual
Page 10

6
LaserLight Installation and Operation Manual
2.4.1
AC Wiring
The LaserLight power supply can run on either 115 or 230 VAC. The AC wiring is run through the cord grip to a
3-position AC terminal block bracket on the inside of the enclosure (shown in Figure 2-5). This bracket can be
removed by loosening the two standoffs and lifting it off. It can then be lowered and pulled outside of the enclosure
to ease wiring connections.
Figure 2-5. Inside Enclosure Backplate Diagram
Refer to the following table for AC wiring connections.
Ensure that a ground wire is attached to the grounding stud located on the enclosure backplate (see
Figure 2-5).
3-pin Terminal Block on Enclosure Back
To Power Supply
To Power Supply
Pin
Wire
Color
Pin
UL Approved Unit
1
Neutral
Blue or White
1
N
2
Hot
Brown or Black
2
L
3
Ground
Green or
Green/Yellow
Ground Tab
Table 2-1. AC Wiring Connections
Grounding
stud
Important