Rice Lake MSI-9750A CellScale RF Portable Indicator User Manual
Page 91
MSI CellScale
®
System • 9750A User Guide Page 91
MEASUREMENT SYSTEMS INTERNATIONAL
Firmware Version 5-XX for 2450 Modems
SET POINTS
1 S 9 S 17 S 25 S
2 S 10 S 18 S 26 S
3 S 11 S 19 S 27 S
4 S 12 S 20 S 28 S
5 S 13 S 21 S 29 S
6 S 14 S 22 S 30 S
7 S 15 S 23 S 31 S
8 S 16 S 24 S 32 S
SP1-NameS SP9 Name-S
SP2-NameS SP10Name-S
SP3-NameS SP11Name-S
SP4-NameS SP12Name-S
SP5-NameS SP13Name-S
SP6-NameS SP14Name-S
SP7-NameS SP15Name-S
SP8-NameS SP16Name-S
2 Set Points DISABLED
2 Set Points ENABLED
5 Clear Latches
Cleared
OPERATOR 1 SP XX
1 Greater Than >
2 > or Equal >=
3 Less Than <
4 < or Equal <=
5 Off
SET POINT VALUE 1
ESC exits no change
ENTER saves value
0-9 replaces value
500
min = 0, max =CAP
^ incs, v decs value
VALUE 1 TYPE
SP
XX
1 Gross
2 Net or Gross
3 Total
4 # of Totals
PREACT VALUE
ESC exits no change
ENTER saves value
0-9 replaces value
10
min = 0, max = CAP
^ incs, v decs value
4 Relationship OR
4 Relationship AND
4 Relationship NONE
VIEW FORMULA SP XX
Set Pt Triggers If
N/G Wt >= 500.0
AND N/G Wt <=1000.0
Set Pt Resets If
N/G Wt < 500.0
OR N/G Wt > 1000.0
1 SP
XX
-SPName- OFF
2 9750 Response
OFF
3 Input Source
XX
4 Output Assign
XX
5 Delay
XXXXXms
6 Latch
OFF
7 Force On
OFF
8 Formula 9 View
AUDIBLE ALARMS SPXX
TRIP RESET
1 Off 6 Off
2 High F 7 High F
3 Med F 8 Med F
4 Low F 9 Low F
5 Warble 0 Warble
F3 Test F4 Test
Len 0 F4 Menu
Max 20 ENT Save
Pos 1
-Alarm String-
ALARM DISPLAY SP XX
TRIP RESET
1 Off 6 Off
2 Large 7 Large
3 Medium 8 Medium
4 Small 4 Small
5 Edit 0 Edit
F3 Test F4 Test
1
ALARM TO COMM1 SP XX
TRIP RESET
1 Off 4 Off
2 On 5 On
3 Edit 6 Edit
F3 Test F4 Test
INPUT SCAN LIST LOC
ESC exits no change
ENTER edits value
0-9 replaces value
1
min = 1 max = 32
^ incs, v decs value
SET POINT DELAY ms
ESC exits no change
ENTER saves value
0-9 replaces value
1000
min = 0, max =10000
^ incs, v decs value
SET POINT XX
1 Audible Alarms OFF
2 Alarm Display OFF
3 Alarm to Comm 2 OFF
SET POINT OUTPUT LIST
ESC exits no change
ENTER edits value
0-9 replaces value
1
min = 1 max = 32
^ incs, v decs value
1 SP
XX
-SPName- ON
1 SP
XX
-SPName- OFF
Len 0 F4 Menu
Max 8 ENT Save
Pos 1
SETPOINT
XX
NAME
1
6 Latch ON
6 Latch OFF
7 Force Output ON
7 Force Output OFF
FORMULA SP XX
1 Operator 1
>
2 Value 1
XXXXXXX
3 Val 1 Type
GROSS
4 Dual Value
OFF
5 Preact
XXXXXXX
6 Deadzone
XXXXXXX
7 View Formula
INPUT SCAN LIST LOC
ESC exits no change
ENTER edits value
0-9 replaces value
1
min = .1 max = 32
^ incs, v decs value
Edit
See General Text Editing
Procedure
1, 2, & 3 menus are similar to Value 1 menus
To Edit Highlighted
TT
Set Point Name
0-9
or
Cursors
0-9
or
Cursors
MASTER SET POINTS
1 Program Set Point
2 Set Points
ENABLED
3 View Status
4 View Status w/Name
5 Clear Latches
6 Mom Timeout Ш.Ш s
PROGRAM SET POINT
ESC exits no change
ENTER edits value
Ø-9 replaces value
1
min = 1 max = 32
^ incs, v decs value
See General Text Editing
Procedure
VALUE 2 ENTRY SP XX
1 Operator 2
>
2 Value 2
XXXXXXX
3 Val 2 Type
GROSS
4 Relationship
to Value 1
AND
5 View Formula
Input Set Point
# for programming
(1-32)
MASTER SET POINTS
ESC
!
SETUP
2
DEF
2
DEF
1
ABC
3
GHI
4
JKL
8
VWX
5
MNO
1
ABC
1
ABC
2
DEF
A
a
1
ALPHA
A
a
1
ALPHA
A
a
1
2
DEF
3
GHI
3
GHI
5
MNO
4
JKL
6
PQR
7
STU
5
MNO
4
JKL
6
PQR
7
STU
1
ABC
2
DEF
3
GHI
4
JKL
ENTER
PROGRAM SET POINT
FORMULA SP
XX
OPERATOR 1 SP
XX
SET POINT VALUE 1
VALUE 1 TYPE SP
XX
VALUE 2 ENTRY SP
XX
PREACT
VIEW FORMULA SP
XX
SET POINT DELAY ms
ALARM TO COMM2 SP
XX
ALARM DISPLAY SP
XX
AUDIBLE ALARMS SP
XX
SET POINT
XX
SET POINT OUTPUT LIST
INPUT SCAN LIST LOC
MOMENTARY TIMEOUT
6
PQR