2 installing the server board, Installing the server board – Kontron NSW1U IP Network Server User Manual
Page 75

Kontron IP Network Server NSW1U
December 2009
Product Guide, rev. 1.4
75
Server Component Replacements—NSW1U Network Server
5.5.2
Installing the Server Board
1. Set the replacement board into place (“B”). Insert the rear edge of the board first, and line up the
I/O ports at the rear of the system.
2. Make sure the standoff locations line up correctly and reinsert the seven screws removed
previously. (“A”)
3. Connect all cables to the server board.
4. Re-install the PDB. For instructions, see
Section 5.4.2, “Installing the Power Distribution Board”
.
5. Re-install the battery and then the battery insulator that comes with the server board accessory/
Section 5.6.1, “Installing the Battery Insulator” on page 78
.
6. Install the PCI riser assembly. For instructions, see
Section 4.4.4, “Installing the Riser Card
Assembly onto the Server Board” on page 54
7. If this is the last task you are performing, replace the processor air duct and the top cover of the
chassis. Reconnect all the external devices and plug in the power cord(s).
Figure 58.
Installing the Server Board
l
B
A
AF000899