6 installing the processor air duct, 1 configuring jumpers on the server board, Installing the processor air duct – Kontron NSW1U IP Network Server User Manual
Page 28: Configuring jumpers on the server board, Air duct, Figure 14

NSW1U Network Server—Server Installations and Upgrades
Kontron IP Network Server NSW1U
Product Guide, rev. 1.4
December 2009
28
3.2.6
Installing the Processor Air Duct
1. Place the processor air duct over the processor socket and three-fan assembly, using caution to
make sure you do not pinch any wires beneath the edges of the air duct.
2. Tighten the screws at the top of the air duct. (
, “A”)
The top of the installed air duct should be flush with the top surface of PCI adapter assembly.
3. Replace the chassis cover if you have completed all work inside of the chassis.
3.3
Internal Configuration and Installation Procedures
The procedures in this section assume that you have powered down the server and removed the
chassis cover as described in
Section 3.2, “General Installation Procedures” on page 25
3.3.1
Configuring Jumpers on the Server Board
The jumpers are located on the S5000PHB server board server board, which is in the rear left side of
the NSW1U Network Server chassis. To configure the jumpers on the server board, besides removing
the chassis cover, you also must remove the processor air duct (see
Processor Air Duct” on page 27
) and the PCI riser card assembly (see
PCI Riser Card Assembly” on page 52
). All other components installed on the server board can remain
in place.
Figure 14.
Removing the Air Duct
AF000880
A
A
B