Server Component Replacements—NSW1U Network Server

5

Server Component Replacements

5.1

Before You Begin

5.1.1

Tools and Supplies Needed

• #1 and # Phillips* (cross-point) screwdrivers (or interchangeable-bit screwdriver with #1 and #2

Phillips bits)

• Anti-static wrist strap and conductive foam pad

5.1.2

System References

All references to left, right, front, top, and bottom assume that you are facing the front of the server,

as it would be positioned for normal operation.

5.2

Replacing the Fan Assemblies

Caution:

Your server does not have hot-swappable fans. Before replacing any of the fans, you

must first take the server out of service, turn off all peripheral devices connected to the

system, turn off the system by pressing the power button, and unplug the power cord

from the system or wall outlet.

The replacement/spare fan set consists of one PCI fan and three CPU fans with resilient fan bumpers

installed to isolate fan vibration from the rest of the system.

5.2.1

Replacing the CPU Fans

1. Remove the chassis cover. For instructions, see

Section 3.2.1, “Removing the Chassis Cover” on

page 25

.

2. Remove the processor air duct that covers the processor and cooling area behind the drive trays.

For instructions, see

Section 3.2.5, “Removing the Processor Air Duct” on page 27

.

3. Disconnect the three fan cables from the Ethernet front panel (EFP) board by squeezing the latch

on each of the three fan cable connectors. See

Figure 26

for the location.

4. Remove the fans from the bracket.