Standard interfaces – pin assignments, Power connector, Serial interface com (rs232) – Kontron Micro Client 3 104 User Manual
Page 59: R 10.1.1 “power connector
10. Standard Interfaces – Pin Assignments
Micro Client 3 – User’s Guide (Version 1.0)
10.
Standard Interfaces – Pin Assignments
Low-active signals are indicated by a minus sign.
10.1.1. Power Connector
Pin Signal Name
3-pin POWER SUBCON (male)
1
0V input (-24 VDC polarity on the unit)
2
NC
3
+24 VDC (input)
10.1.2. Serial interface COM (RS232)
Pin Signal Name
9-pin D-SUB Connector (male)
1
DCD (Data Carrier Detect)
2
RXD (Receive Data)
3
TXD
(Transmit Data)
4
DTR
(Data Terminal Ready)
5
GND (Signal Ground)
6
DSR (Data Set Ready)
7
RTS
(Request to Send)
8
CTS
(Clear to Send)
9
RI
(Ring Indicator)
www.kontron.com