Electrical specifications, Environmental specifications – Kontron Micro Client 3 104 User Manual
Page 50

9. Technical Data
Micro Client 3 – User’s Guide (Version 1.0)
9.1. Electrical Specifications
9.1.1. Electrical Specifications for MC 3 104/121/150/170/3W 156 System
System Type
Product Designation
Input
Micro Client 3
(MC 3)
MC 3 104
24VDC (+/- 20% = 18 – 30VDC)
0.7A
Nom
(~20W)
MC 3 121
24VDC (+/- 20% = 18 – 30VDC)
0.8A
Nom
(~
22W)
MC 3 150
24VDC (+/- 20% = 18 – 30VDC)
0.95A
Nom
(~
30W)
MC 3 170
24VDC (+/- 20% = 18 – 30VDC)
1.8A
Nom
(~
45W)
MC 3W 156
24VDC (+/- 20% = 18 – 30VDC)
1.05A
Nom
(~
32W)
9.2. Environmental Specifications
Thermal Management
passive cooling (for CPU and system)
Operating Temperature
0 … +50 °C (32 … 122 °F) for MC 3 104/121/150/170
0 … +55 °C (32 … 131 °F) for MC 3W 156 (*options : max. 50 °C)
Storage/Transit Temperature
-10 … +60 °C (14 … 140 °F)
Operating Rel. Humidity
10% to 90% @ 35 °C, non-condensing
Storage/Transit Rel. Humidity
10% to 90% @ 35 °C, non-condensing
Operating Altitude
Up to 2,000 m (6,600 ft)
Storage / Transit Altitude
Up to 4,600 m (15,000 ft)
Operating Shock
15 G, 11 ms duration, half-sinus
Storage / Transit Shock
30 G, 11 ms duration, half-sinus
Operating Vibration
10–500 Hz: 1.0 G/3axis
Storage / Transit Vibration
10–500 Hz: 2.0 G/3axis
Protection Class
IP65 (Front Panel Side), IP20 (Rear)
48