Watchdog mode sdo, Interrupt config sdo, Wd active time sdo – Kontron AM5010 BIOS User Manual
Page 103
AM4010/AM4011/AM5010 BIOS
OEM Feature
ID 1022-2060, Rev. 2.0
Page 93
Watchdog Mode
SDO
Optimal and Fail-Safe default setting: Timer Only
Interrupt Config
SDO
Use this function to specify the type of interrupt used when the Watchdog is operated in Inter-
rupt or Cascade mode.
Optimal and Fail-Safe default setting: Disabled
WD Active Time
SDO
Optimal and Fail-Safe default setting: 125 ms
SETTING
DESCRIPTION
Timer Only
Use this setting to specify that the Watchdog is to be operated in Timer Only mode.
Reset
Use this setting to specify that the Watchdog is to reset the system if it is not retriggered
within the selected time.
Interrupt
Use this setting to specify that the Watchdog is to generate an interrupt if it is not retriggered
within the selected time.
Cascade
(Interrupt + Reset)
Use this setting to specify that the Watchdog is to be operated in Cascade mode.
In this mode, if the Watchdog is not retriggered within the selected time, an interrupt is gen-
erated and the Watchdog is automatically retriggered. If the Watchdog subsequently times
out again, the system will be reset.
If the Watchdog is retriggered normally after the interrupt, the next timeout will result in the
generation of an interrupt and the automatic retriggering of the Watchdog.
SETTING
DESCRIPTION
Disabled
Use this setting to disable this function.
IRQ5
Use this setting to specify that the Watchdog is to generate an IRQ5 interrupt when operated
in Interrupt or Cascade mode.
NMI
Use this setting to specify that the Watchdog is to generate a Non-Maskable Interrupt (NMI)
when operated in Interrupt or Cascade mode.
SETTING
DESCRIPTION
125 ms
250 ms
500 ms
1 s
2 s
4 s
8 s
16 s
32 s
64 s
128 s
256 s
Use one of these settings to specify the time after which the action selected occurs if the
Watchdog timer is not retriggered.