High side lite base installation, Fig. # 77, Fig. # 76 – EFCO 403 Series Storefront User Manual
Page 71

EFCO CORPORATION 1/2013 PART NO. Y001
Page 71 of 94
Series 401,402, & 403 Installation Instructions
( for interior use only w/o sill flashing )
in a continuous bead of sealant that will run vertical to vertical. When a
CONTINUOUS w/o SILL FLASHING -
adaptor (#9149) can be utilized. Locate the base adaptor pieces 6" from
sill flashing is being incorporated, the use of 4" long pieces of the base
the verticals and 24" on center, with a minimum of 3 per DLO.
4" LONG PIECE w/ SILL FLASHING
Fill and tool sealant
onto the flashing.
into the pocket
to divert water
Side lite base adaptor
# 9149
Fig. # 77 below.
SYSTEM SILL FLASHING
screws with sealant
Cover the heads of all attachment
Horizontal shear block
sealant bead
Continuous
CE
NT
ER
LIN
E
# K172/1G80
# K173/9248
# K122/9148
Set in sealant.
Fig. # 77
Cut the sill flashing to the day lite opening of the module and then set it
bead under the side lite sill flashing.
TO NEXT VERTICAL MULLION
REFER TO SECTION III F FOR SIDE LITE BASE PREP.
pocket to the next vertical.
floor at the inside line of the glazing
continuous bead of sealant on the
Start at the door jamb and run a
SECTION IV: D.
SEALANT BEAD CONTINUES
Be sure to tie the sealant bead from under
the threshold and under the jamb member
through the glazing pocket to the sealant
STEP 2)
NOTE:
STEP 1)
HIGH SIDE LITE BASE
INSTALLATION
Shear block &
Fig. # 76
screws
# K122/9148
# K173/9248
# K172/1G80
DOOR JAMB
Set in sealant.