CHAPTER 2: INSTALLATION

2.1

ABS ENCLOSURE (800 Series)

For indicators contained in the standard ABS enclosure, the rear panel contains all

connectors necessary to make the appropriate connections to the weigh platform, printer,

remote display and power supply.

DC Jack

Serial

Port

LOAD CELL

Setup/Calibration Switch

Port

Figure 2-1: 800 Series ABS Enclosure Rear Panel

2.1.1 CONNECTING THE WEIGH PLATFORM

The indicators mounted in an ABS enclosure ship with a 15 ft shielded load cell

cable for connection to weigh platform’s load cell(s) or junction box.
1. Plug the cable’s 14-pin Centronics-type connector into the load cell port on the

rear panel of the indicator.

2. Wire the bare wires and shield to the weigh platform’s load cell(s) or junction

box using the color codes shown in Figure 2-2.

Color

Wire Name

RED

+Excitation

BLK

–Excitation

GRN

+Signal

WHT

–Signal

Figure 2-2: Color Codes for Shielded Load Cell Cable

3. If you do not wish to use the shielded load cell cable, you may use own,

following the pin assignments shown in Figure 2-3. (A 14-pin Male Centronics-

type connector is required).

Pin Nos.

Pin Name

1/8

+Excitation

3/10

–Excitation

5/12

+Signal

7/14

–Signal

7

1

5

3

14

12

10

8

Figure 2-3: Pin assignments for the Load Cell Port