beautypg.com

Salter Brecknell 800 Series User Manual

Page 37

background image

APPENDIX A: SPECIFICATIONS

ANALOG SPECIFICATIONS

Full Scale Input Signal

30mV, including dead load

Minimum Sensitivity - Non H-44

0.4

µ

V / grad

Minimum Sensitivity - H-44

1.0

µ

V / grad

Input Impedance

30M

, typical

Internal Resolution

Approximately 260,000 counts

Display Resolution

50,000 display division max

Measurement Rate

10 Meas/sec, nominal

System Linearity

Within 0.02% of FS

Calibration Method

Software Calibration, with long term storage in EEPROM

Excitation Voltage

+10VDC, 8 x 350

load cells

DIGITAL SPECIFICATIONS

Microcomputer

Intel 80C32

Program Memory:

64K x 8, external to

µ

C

EEPROM:

64 x 16, external to

µ

C

Digital Filtering

Software selectable

RTC

Dallas DS1302 w/ Gold Cap

SERIAL COMMUNICATIONS

Serial Port

Full Duplex, 1200, 2400, 4800, 9600 Baud

8 data bits, no parity, 1 stop bit

7 data bits, odd parity, 1 stop bit

7 data bits, even parity, 1 stop bit

7 data bits, no parity, 2 stop bits

OPERATOR INTERFACE

Display - TI-1600/20

1" (25.4 mm) 7-segment, Led, 6 Digit

Display - TI-1610/30

0.8" (19 mm) 7-segment, Liquid Crystal, 6 Digit

Additional Symbols

Net, Gross, Stable, Tare, lb, kg, Pieces, Zero, APW, Disp T

Keyboard

18-key flat membrane panel

POWER

Standard AC Input

110/220 VAC , 50/60 Hz

Optional AC Adapter

12 VDC, 800mA Female

DC Power Consumption - TI-1600/20

200mA + 30mA/350

Load Cell

DC Power Consumption - TI-1610/30

80mA + 30mA/350

Load Cell

ENVIRONMENTAL

Operating Temperature

–10° to +40

°

C

Storage Temperature

-25° to +70

°

C

MECHANICAL

Overall Dimensions (L x W x H) –

TI-1600/TI-1610

12.2” x 3.9" x 8.1" (310mm x 100mm x 205mm)

Overall Dimensions (L x W x H) –

TI-1620/TI-1630

11.8” x 3.9" x 7.7" (300mm x 100mm x 195mm)

APPROVALS

NTEP

Class

III/IIIL

COC 99-017

Canadian Legal Branch of

Metrology

Class

III

Approval No. AM-5305