Salter Brecknell 800 Series User Manual
Page 39

B.1.1.1 RECOGNIZED HOST COMMANDS
“P”
- This command is sent to the indicator to print the indicated display.
The indicator will not respond if the scale is in motion, positive
overload or negative overload.
“Z”
- This command is sent to the indicator to zero the scale. The indicator
will not respond if the scale is in motion, positive overload or negative
overload. The indicator will also not respond if it is not in gross mode
or within the zero range specified in F4 of the Setup Menu.
“T”
- This command is sent to the indicator to tare the scale. The indicator
will not respond if the scale is in motion, positive overload or negative
overload. The indicator will also not respond if it displaying a negative
gross value.
“G”
- This command is sent to the indicator to revert to gross mode. The
indicator will not respond if the scale is in motion, positive overload or
negative overload. The indicator will also not respond if it is not in net
mode.
“N”
- This command is sent to the indicator to revert to net. The indicator
will not respond if the scale is in motion, positive overload or negative
overload. The indicator will also not respond if it is not in gross mode
or a tare has yet to be established.
“C”
- This command is sent to the indicator to toggle among the configured
units.
B.1.2 PRINT TICKET MODE
The Print Ticket Mode is designed specifically for a serial printer. Figure B-3 shows the
fixed format of the print ticket.
For printers with limited buffers, this mode supports DTR pin handshaking by enabling A7
in the User Menu. The DTR pin from the serial printer is wired to the
indicator’s RXD pin which then functions as a CTS pin. Figure B-4 shows a
suggested cable diagram for interfacing to a serial printer. Refer to the
printer’s user manual to confirm whether or not it supports the DTR pin.
The cable depicted in Figure B-4 can be used even if the printer does not
support the DTR pin.
NOTES:
1. The TARE and NET fields are not printed unless a tare has been
established in the system.
2. The ID number field is not printed if it is disabled in A4 of the User Menu.
3. The Time field is not printed if it is disabled in A8 of the User Menu.
4. The Date number field is not printed if it is disabled in A11 of the User
Menu.