beautypg.com

Salter Brecknell 800 Series User Manual

Page 33

background image

7.3.5 PIECE COUNTING - UNKNOWN AVERAGE PIECE WEIGHT

This mode is used to indicate the number of pieces of an item you have placed on

the scale’s platform and is accessed by pressing the UNITS key. To ensure

accuracy, the parts you are counting must be consistent in weight.

The indicator uses the sampling method to determine the average piece weight

(APW) of the items you wish to count. When sampling items, always count the parts

in your hand and place them on the platform all at once. If the APW of the items is

too light or the total weight of the sample is too light, accuracy cannot be

guaranteed. You will get an error message, but piece counting will still be allowed.

For your convenience, the 800 series indicator retains the APW value even when

the unit is powered off.

NOTE

: Piece counting must be enabled in the Setup Menu in order to use this

feature. See Chapter 4 for more information.

1. If the items you will be counting require a container, you should first tare off the

weight of that container by following the appropriate procedure in either Section

7.3.2 or Section 7.3.3.

2. Press the SAMPLE key. The indicator displays “10 0” and is prompting you to

place ten identical items on the platform.

NOTE:

If you wish to change the sample number, simply press the SAMPLE key

repeatedly until the desired sample number appears. Available choices are 20,

50, 100, 200 and 500.

3. Place the sample items on the platform all at once and allow the weight indication

to stabilize. If the total weight of the sample is sufficient, the zero indicated after

the sample number will change to a “–“. For example, “10 –“. If it does not,

repeat Step 2 to increment the sample size. If you cannot obtain the proper

message after 500 pieces, the APW of the items you wish to count is too light for

your scale to process accurately.

4. Press the SAMPLE key again to take the sample. The indicator now displays the

number of pieces on the platform.

5. To exit the piece count mode, press the UNITS key. The same APW value will

remain in scale memory until you repeat Step # 2.

NOTE

: There is an alternative method to the one described above which allows you

to enter non-standard sample values. This alternative procedure follows below.

1. If the items you will be counting require a container, you should first tare off the

weight of that container by following the appropriate procedure in either Section

7.3.2 or Section 7.3.3.

2. Place the sample items on the platform all at once and allow the weight indication

to stabilize.

3. Use the numeric keys to enter the number of items you have placed on the

platform.

4. Press the SAMPLE key to take the sample. If the sample size and weight is

sufficient, the indicator now displays the number of pieces on the platform.

5. To exit the piece count mode, press the UNITS key. The same APW value will

remain in scale memory until you repeat Step # 2.