Salter Brecknell 800 Series User Manual
Page 20

SUB-MENU
TITLE
SELECTIONS
F1
Graduations
12,000
20,000
30,000
40,000
50,000
F3
Zero Tracking Band (SAZSM) 0d
5d
F4
Zero Reset Range
100% (Canada Only)
F5
Motion Band
3d
5d
10d
F6
Digital Filter
1
2
4
F12
Custom Unit
1
F13
Piece Count
1
Table 4-1: Invalid Setup Menu selections for commercial applications
4.2
SETUP MENU PROCEDURES
This section provides instructions for all of the Setup Menu procedures with the exception
of the Calibration procedures (F16 through F20) which can be found in Chapter 6.
4.2.1 CUSTOM UNIT MULTIPLIER (F11)
The custom unit multiplier is the conversion factor that you would multiply the
calibration unit by in order to obtain the custom unit of weight. For example, if
your scale is calibrated in pounds and you wish to display weight in ounces, you
would enter in a multiplier value of 0.0625. The indicator automatically
determines the proper display increment for your custom unit.
1.
While in the Setup mode, scroll to "
F 11
", then scroll down once using the
#2
key to enter the custom unit multiplier menu.
2. The display will momentarily show "
C U
" for the custom unit, followed the
current value of the custom unit multiplier.
3. Use the front panel numeric keys to key-in the actual multiplier value. If you
make a mistake, press the CL key to clear your entry and start over.
4. After entering the exact value, press the NET/GROSS key to save the
custom unit multiplier value. The display will show "
EndCU
" momentarily,
then revert back up to F11.