SUB-MENU

TITLE

SELECTIONS

F1

Graduations

12,000

20,000

30,000

40,000

50,000

F3

Zero Tracking Band (SAZSM) 0d

5d

F4

Zero Reset Range

100% (Canada Only)

F5

Motion Band

3d

5d

10d

F6

Digital Filter

1

2

4

F12

Custom Unit

1

F13

Piece Count

1

Table 4-1: Invalid Setup Menu selections for commercial applications

4.2

SETUP MENU PROCEDURES

This section provides instructions for all of the Setup Menu procedures with the exception

of the Calibration procedures (F16 through F20) which can be found in Chapter 6.

4.2.1 CUSTOM UNIT MULTIPLIER (F11)

The custom unit multiplier is the conversion factor that you would multiply the

calibration unit by in order to obtain the custom unit of weight. For example, if

your scale is calibrated in pounds and you wish to display weight in ounces, you

would enter in a multiplier value of 0.0625. The indicator automatically

determines the proper display increment for your custom unit.

1.

While in the Setup mode, scroll to "

F 11

", then scroll down once using the

#2

key to enter the custom unit multiplier menu.

2. The display will momentarily show "

C U

" for the custom unit, followed the

current value of the custom unit multiplier.

3. Use the front panel numeric keys to key-in the actual multiplier value. If you

make a mistake, press the CL key to clear your entry and start over.

4. After entering the exact value, press the NET/GROSS key to save the

custom unit multiplier value. The display will show "

EndCU

" momentarily,

then revert back up to F11.