0101-xx
CPU test failed.
Replace the system board and retest.
0102-xx
Coprocessor error.
1. Run Computer Checkup or Computer Setup and retest.
2. Replace the system board and retest.
0103-xx
DMA controller failed.
The following step applies to error codes 0103-xx through 0106-xx:
0104-xx
Interrupt controller failed.
Replace the system board and retest.
0105.xxx
Port error.
0106-xx
Keyboard controller self-test failed.
0107-xx
CMOS RAM test failed.
The following steps apply to error codes 0107-xx through 0109-xx:
0108-xx
CMOS interrupt test failed.
1. Replace the battery/clock module and retest.
0109-xx
CMOS clock test failed.
2. Replace the system board and retest.
0110-xx
Programmable timer test failed.
The following step applies to error codes 0110-xx through 0113-01:
0113-01
Protected mode test failed.
Replace the system board and retest.
0114-01
Speaker test failed.
1. Verify the speaker connection.