beautypg.com

Cabletron Systems 2H28-08R User Manual

Page 76

background image

Chapter 5: Local Management

5-28

2H28-08R SmartSwitch 2208 User’s Guide

2.

Press the SPACE bar to choose either ENABLED or DISABLED.
The COM port must be ENABLED if it will be used for Local
Management or UPS applications. Select DISABLED if you wish to
disable the COM port for device security.

Figure 5-12

COM Port Warning Screen

3.

Use the arrow keys to highlight YES. Press ENTER.

4.

If you ENABLED the port, proceed to step 5. If you DISABLED the
port, use the arrow keys to highlight SAVE at the bottom of the screen,
then press ENTER.

!

CAUTION

If the COM port is reconfigured without a valid IP address set
on the device, the message shown in

Figure 5-11

displays.

Do not continue unless the outcome of the action is fully
understood.

NOTE

If the 2H28-08R has been configured with a valid IP Address,
this screen will not appear.
Go to Step 4 if you do not get the screen.

WARNING

174252

THE COM PORT HAS BEEN RECONFIGURED AND THERE IS NO IP

ADDRESS SET FOR THIS DEVICE. YOU WILL NO LONGER BE ABLE

TO MANAGE THIS BOARD. DO YOU STILL WISH TO RECONFIGURE

THIS COM PORT?

YES

NO

Event Message Line