beautypg.com

3 troubleshooting checklist, Troubleshooting checklist -5 – Cabletron Systems 2H28-08R User Manual

Page 47

background image

Troubleshooting Checklist

2H28-08R SmartSwitch 2208 User’s Guide

4-5

4.3

TROUBLESHOOTING CHECKLIST

If the 2H28-08R is not working properly, refer to

Table 4-4

for a checklist

of possible problems, causes, and recommended actions to resolve the
problem.

Table 4-4

Troubleshooting Checklist

Problem

Possible Cause

Recommended Action

All LEDs are OFF.

Loss of power.

Check for proper connection
of the power cables and
access to live outlets.

Installed improperly.

Check the installation. See

Chapter 3

for details.

No Local
Management
Password screen.

Autobaud is enabled.

Press ENTER (RETURN) key
(may take up to four times).

Terminal setup is not
correct.

Refer to

Chapter 5

for proper

setup procedures.

Improper console cable
used.

Refer to

Appendix A

for

proper console port pinouts.

Cannot contact the
2H28-08R from
in-band
management.

Using incorrect
Community Name.

Refer to

Chapter 5

for Community Name setup.

The 2H28-08R does not
have an IP address
assigned.

Refer to

Chapter 5

for IP

address assignment
procedure.

Port is disabled.

Enable port.

No link to device.

Check link to device.

Port(s) goes into
standby for no
apparent reason.

The 2H28-08R detected
a loop condition.

1. Review network design and

delete unnecessary loops.

2. Contact the Cabletron

Systems Global Call Center
if problem still exists.

User parameters (IP
address, Device and
Module name, etc.)
were lost when the
2H28-08R power
was cycled or the
front panel RESET
button was pressed.

Mode switch (7), NVRAM
Reset, was changed
sometime before either
cycling power or
pressing the RESET
button causing the
user-entered parameters
to reset to factory default
settings.

1. Reenter the lost

parameters as necessary.

2. Call the Cabletron Systems

Global Call Center if
problem still exists.