Chapter 3: Installation

3-4

2H28-08R SmartSwitch 2208 User’s Guide

Figure 3-1

Tabletop or Shelf Installation

3.4.2

Rackmount Installation

To install the 2H28-08R in a 19-inch rack, the device is shipped with a
rackmount kit containing the rackmount brackets, mounting screws, and a
strain-relief bracket for cable management.

Guidelines for the Rackmount Installation

The installation site must be within reach of the network cabling and meet
the requirements listed below:

An appropriate grounded power receptacle must be located within
seven feet of the device.

Maintain a temperature of between 5

°

C (41

°

F) and 40

°

C (104

°

F) at

the installation site with fluctuations of less than 10

°

C (18

°

F) per hour.

WARNING

Before installing the 2H28-08R

into a rack, ensure that the rack

supports the device(s) without compromising the stability of the
rack. Otherwise, personal injury and/or equipment damage
may result.

!

CAUTION

To ensure proper ventilation and prevent overheating, leave a
minimum clearance space of 5.1 cm (2.0 in) at the left, right,
and rear of the 2H28-08R.

2251-06

A = 15 cm (6 in)
B = 57.2 cm (22.5 in)
C = 53 cm (21 in)

C

B

A

D

D = 213 cm (7 ft)