Dell PowerEdge R910 User Manual
Page 35

About Your System
35
E1A15
SAS cable B
failure.
Check
connection.
SAS cable B is missing or
bad.
Reseat the cable. If the
problem persists, replace
cable.
If the problem persists,
E1A1D
Control panel
USB cable not
detected.
Check cable.
USB cable to the control
panel is missing or bad.
Reseat the cable. If the
problem persists, replace
cable.
If the problem persists,
E2010
Memory not
detected.
Inspect
DIMMs.
No memory was detected in
the system.
Install memory or reseat
the memory risers and
memory modules. See
E2011
Memory
configuratio
n failure.
Check DIMMs.
Memory detected, but is not
configurable. Error detected
during memory
configuration.
E2012
Memory
configured
but unusable.
Check DIMMs.
Memory configured, but is
unusable.
E2013
BIOS unable
to shadow
memory. Check
DIMMs.
The system BIOS failed to
copy its flash image into
memory.
Code
Text
Causes
Corrective Actions
book.book Page 35 Tuesday, December 4, 2012 3:11 PM