Dell PowerEdge R910 User Manual

Page 28

background image

28

About Your System

E1313

Fan

redundancy

lost. Check

fans.

The system is no longer fan

redundant. Another fan

failure would put the system

at risk of over-heating.

Check LCD for additional

scrolling messages. See

"Troubleshooting a Fan"

on page 180.

E1314

Critical

system

cooling loss.

Check fans.

All fans have been removed

from system.

Ensure that the fans are

properly installed. See

"Troubleshooting a Fan"

on page 180.

E1410

System Fatal

Error

detected.

A fatal system error has been

detected.

Check LCD for additional

scrolling messages.

Remove AC power to the

system for 10 seconds and

restart the system.
If the problem persists,

see "Getting Help" on

page 203.

E1414

CPU # temp

exceeding

range. Check

CPU heatsink.

Specified processor is out of

acceptable temperature

range.

Ensure that the processor

heat sinks are properly

installed. See

"Troubleshooting the

Processors" on page 190

and "Troubleshooting

System Cooling

Problems" on page 180.

E1418

CPU # not

detected.

Check CPU is

seated

properly.

Specified processor is

missing or bad, and the

system is in an unsupported

configuration.

Ensure that the specified

processor is properly

installed. See

"Troubleshooting the

Processors" on page 190.

E141C

Unsupported

CPU configur-

ation. Check

CPU or BIOS

revision.

Processors are in an

unsupported configuration.

Ensure that your

processors match and

conform to the type

described in the processor

technical specifications

outlined in your system’s

Getting Started Guide.

Code

Text

Causes

Corrective Actions