About Your System
33
E1716
Chipset IERR
Bus
##
Dev
##
Function
##
.
Review &
clear SEL.
The system BIOS reported a
chipset internal error that
resides in bus ##, device
##, function ##.
Check the SEL for more
information, and then
clear the SEL. Remove
AC power to the system
for 10 seconds, and restart
the system.
If the problem persists,
E1717
CPU
#
internal
error. Review
& clear SEL.
The system BIOS
determined that the
specified processor has had
an internal error.
Check the SEL for more
information, and then
clear the SEL. Remove
AC power to the system
for 10 seconds, and restart
the system.
If the problem persists,
E171F
PCIe fatal
error on Bus
## Device ##
Function ##.
The system BIOS has
reported a PCIe fatal error
on a component that resides
in PCI configuration space
at bus ##, device ##,
function ##.
Remove and reseat the
PCIe expansion cards. If
the problem persists, see
PCIe fatal
error on Slot
#. Review &
clear SEL.
The system BIOS has
reported a PCIe fatal error
on a component that resides
in the specified slot.
Reinstall the expansion-
card riser. See "Expansion
If the problem persists,
the riser card or system
board is faulty. See
E1810
Hard drive ##
fault. Review
& clear SEL.
The specified hard drive
experienced a fault.
Code
Text
Causes
Corrective Actions
book.book Page 33 Tuesday, December 4, 2012 3:11 PM