About Your System
E1211
RAID
Controller
battery
failure.
Check
battery.
RAID battery is either
missing, bad, or unable to
recharge due to thermal
issues.
Reseat the RAID battery
connector. See "Installing
E1216
3.3V
Regulator
failure.
Reseat PCIe
cards.
3.3V voltage regulator failed. Remove and reseat the
PCIe expansion cards. If
the problem persists, see
E1219
Disk
Backplane
power
failure.
Check BP
power cable.
Storage backplane voltage
regulator has failed.
Remove and reseat the
backplane. If the problem
E1222
CPU # VCACHE
Regulator
failure.
Contact
support.
Processor voltage regulator
failed.
Reseat the processor(s).
Processors" on page 190.
If the problem persists,
E122C
CPU Power
Fault. Power
cycle AC.
A power fault was detected
when powering up the
processor(s).
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
E122E
On-board
regulator
failed. Call
support.
One of the on-board voltage
regulators failed.
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
Code
Text
Causes
Corrective Actions
book.book Page 26 Tuesday, December 4, 2012 3:11 PM