beautypg.com

Dell PowerEdge R910 User Manual

Page 26

background image

26

About Your System

E1211

RAID

Controller

battery

failure.

Check

battery.

RAID battery is either

missing, bad, or unable to

recharge due to thermal

issues.

Reseat the RAID battery

connector. See "Installing

the RAID Battery" on

page 146 and

"Troubleshooting System

Cooling Problems" on

page 180.

E1216

3.3V

Regulator

failure.

Reseat PCIe

cards.

3.3V voltage regulator failed. Remove and reseat the

PCIe expansion cards. If

the problem persists, see

"Troubleshooting

Expansion Cards" on

page 189.

E1219

Disk

Backplane

power

failure.

Check BP

power cable.

Storage backplane voltage

regulator has failed.

Remove and reseat the

backplane. If the problem

persists, see "Getting

Help" on page 203.

E1222

CPU # VCACHE

Regulator

failure.

Contact

support.

Processor voltage regulator

failed.

Reseat the processor(s).

See "Troubleshooting the

Processors" on page 190.
If the problem persists,

see "Getting Help" on

page 203.

E122C

CPU Power

Fault. Power

cycle AC.

A power fault was detected

when powering up the

processor(s).

Remove AC power to the

system for 10 seconds and

restart the system.
If the problem persists,

see "Getting Help" on

page 203.

E122E

On-board

regulator

failed. Call

support.

One of the on-board voltage

regulators failed.

Remove AC power to the

system for 10 seconds and

restart the system.
If the problem persists,

see "Getting Help" on

page 203.

Code

Text

Causes

Corrective Actions

book.book Page 26 Tuesday, December 4, 2012 3:11 PM