Dell POWEREDGE R515 User Manual
Page 46
46
About Your System
Memory set to
minimum
frequency.
The memory frequency may
be intentionally set lower for
power conservation.
If not an intentional setting,
check any other system
messages for possible causes.
The current memory
configuration may support
only the minimum frequency.
Ensure that your memory
configuration supports the
higher frequency.
See "General Memory
Memory tests
terminated by
keystroke.
POST memory test was
terminated by pressing the
spacebar.
Information only.
MEMTEST lane
failure
detected on x
Invalid memory
configuration. Mismatched
memory modules are
installed.
Ensure that the memory
modules are installed in a
valid configuration.
See "General Memory
No boot device
available.
Faulty or missing optical
drive subsystem, hard drive,
or hard drive subsystem, or
no bootable USB key
installed.
Use a bootable USB key,
optical drive, or hard drive.
If the problem persists,
page 57 for information on
setting the order of boot
devices.
Message
Causes
Corrective Actions
book.book Page 46 Tuesday, August 24, 2010 1:47 PM