46

About Your System

Memory set to
minimum
frequency.

The memory frequency may

be intentionally set lower for

power conservation.

If not an intentional setting,

check any other system

messages for possible causes.

The current memory

configuration may support

only the minimum frequency.

Ensure that your memory

configuration supports the

higher frequency.

See "General Memory

Module

Installation Guidelines" on

page 105.

Memory tests
terminated by
keystroke.

POST memory test was

terminated by pressing the

spacebar.

Information only.

MEMTEST lane
failure
detected on x

Invalid memory

configuration. Mismatched

memory modules are

installed.

Ensure that the memory

modules are installed in a

valid configuration.

See "General Memory

Module

Installation Guidelines" on

page 105.

No boot device
available.

Faulty or missing optical

drive subsystem, hard drive,

or hard drive subsystem, or

no bootable USB key

installed.

Use a bootable USB key,

optical drive, or hard drive.

If the problem persists,

see "Troubleshooting an

Optical Drive" on page 168,

"Troubleshooting a USB

Device" on page 158,

"Troubleshooting an Internal

USB Key" on page 167, and

"Troubleshooting a Hard

Drive" on page 169.

See "Using the System Setup

Program and

UEFI Boot Manager" on

page 57 for information on

setting the order of boot

devices.

Message

Causes

Corrective Actions

book.book Page 46 Tuesday, August 24, 2010 1:47 PM