About Your System
E1114 Ambient Temp
exceeds
allowed range.
Ambient temperature has
a reached a point outside
of the allowed range.
E1116 Memory
disabled,
temp above
range.
Power
cycle AC.
Memory has exceeded
allowable temperature and
has been disabled to
prevent damage to the
components.
Remove AC power to the
system for 10 seconds and
restart the system.
See "Troubleshooting
If the problem persists,
E1210 Motherboard
battery
failure.
Check
battery.
CMOS battery is missing
or the voltage is outside of
the allowable range.
E1211 RAID
Controller
battery
failure.
Check
battery.
RAID battery is either
missing, bad, or unable
to recharge due
to thermal issues.
Reseat the RAID battery
connector. See "Installing
E1216 3.3V Regulator
failure.
Reseat PCIe
cards.
3.3 V voltage regulator
has failed.
Remove and reseat the
PCIe expansion cards.
If the problem persists,
E1229 CPU # VCORE
Regulator
failure.
Reseat CPU.
Specified processor
VCORE voltage
regulator has failed.
Reseat the processor(s).
Processors" on page 174.
If the problem persists,
Code
Text
Causes
Corrective Actions
book.book Page 28 Tuesday, August 24, 2010 1:47 PM