Dell POWEREDGE R515 User Manual
Page 34
34
About Your System
E1920 iDRAC6 Upgrade
Failed
The iDRAC6 Express
Card is not installed
properly or the card is bad.
Reseat the iDRAC6
Express Card. If the
problem persists, see
E1A14 SAS cable A
failure.
Check
connection.
SAS cable A is missing
or bad.
Reseat the cable. If the
problem persists,
replace cable.
If the problem persists,
E1A15 SAS cable B
failure.
Check
connection.
SAS cable B is missing
or bad.
Reseat the cable. If the
problem persists,
replace cable.
If the problem persists,
E1A1D Control panel
USB cable not
detected.
Check cable.
USB cable to the control
panel is missing or bad.
Reseat the cable.
If the problem persists,
replace cable.
If the problem persists,
E2010 Memory not
detected.
Inspect DIMMs.
No memory was detected
in the system.
Install memory or reseat
memory modules.
E2011 Memory
configuration
failure.
Check DIMMs.
Memory detected,
but is not configurable.
Error detected during
memory configuration.
Code
Text
Causes
Corrective Actions
book.book Page 34 Tuesday, August 24, 2010 1:47 PM