beautypg.com

Dell POWEREDGE R515 User Manual

Page 33

background image

About Your System

33

E1711 PCI parity

error on #.
Review & clear
SEL.

The system BIOS has

reported a PCI parity

error on a component

that resides in PCI

configuration space at

bus ##, device ##,

function ##.

Remove and reseat the

PCIe expansion cards.

If the problem persists,

see "Troubleshooting

Expansion Cards" on

page 172.

E1712 PCI system

error on #.
Review & clear
SEL.

The system BIOS has

reported a PCI system

error on a component

that resides in PCI

configuration space at

bus ##, device ##,

function ##.

Remove and reseat the

PCIe expansion cards.

If the problem persists,

see "Troubleshooting

Expansion Cards" on

page 172.

E1714 Unknown error.

Review & clear
SEL.

The system BIOS has

determined there has

been an error in the

system, but is unable to

determine its origin.

Check the SEL for

more information and

then clear the SEL.

Remove AC power to the

system for 10 seconds and

restart the system.
If the problem persists,

see "Getting Help" on

page 187.

E171F PCI fatal

error on #.
Review & clear
SEL.

The system BIOS has

reported a PCIe fatal

error on a component

that resides in PCI

configuration space at

bus ##, device ##,

function ##.

Remove and reseat the

PCIe expansion cards.

If the problem persists,

see "Troubleshooting

Expansion Cards" on

page 172.

E1810 Hard drive ##

fault. Review
& clear SEL.

The specified hard drive

has experienced a fault.

See "Troubleshooting a

Hard Drive" on page 169.

E1812 Hard drive ##

removed.
Check drive.

The specified hard

drive has been removed

from the system.

Information only.

Code

Text

Causes

Corrective Actions

book.book Page 33 Tuesday, August 24, 2010 1:47 PM