beautypg.com

Troubleshooting, General troubleshooting, Troubleshooting general troubleshooting – Great Plains YP4025F-1670 Operator Manual User Manual

Page 95

background image

2014-09-08

Table of Contents

Index

401-571M

Great Plains Manufacturing, Inc.

Table of Contents

Index

91

Troubleshooting

General Troubleshooting

Problem

Cause

Solution

Planting too
little

Incorrect seed size for meter wheel
can cause skips

Replace meter wheels to match seed

Meter drive not engaged

Engage drive coupler, page 75

Worn meter components

Replace worn components

Incorrect seed rate.

Check seed rate information.

Excessive field speed.

Reduce field speed.

Seed size and weight may vary.

Finger meter brush may need adjustment, page 85.

Brush too tight on finger meter

Adjust brush, page 85.

Incorrect fan air flow

Adjust fan speed and/or fan baffle. See page 61

Excessive gaps between planter
passes.

Adjust marker, page 60.

Plugged row-unit seed tube.

Raise planter, expose bottom of seed tube and clean out.

Thrown or worn drive chains

Check drive chains.

Worn/rusted sprockets, chains and/or
chain idlers

Replace sprockets, chains and/or chain idlers.

Loose finger assemblies in finger
meters

Have dealer service meters.

Speed sensor calibration

Perform calibration per DICKEY-john

®

documentation with

planter lowered.

Speed sensor angle.

With planter lowered, check radar speed sensor angle per
DICKEY-john

®

recommendations.

Meter wheel or finger pickup has
fewer cells than indicated on seed
rate chart.

Charts are based on either 6 finger or 12 finger meters or
various wheel cell counts.

Planting too
much

Incorrect seed size for meter wheel
can cause doubles

Replace meter wheels to match seed

Worn meter components

Replace worn components

Meter clean-out door left open

Close door

Incorrect seed rate.

Check seed rate information in the seed monitor manual.

Actual field size is different.

Verify field size.

Excessive overlap.
Irregular shaped field.

Adjust marker, page 60.

Speed sensor calibration

Perform calibration per DICKEY-john

®

documentation with

planter lowered.

Speed sensor angle.

With planter lowered, check radar speed sensor angle per
DICKEY-john

®

recommendations.

Brush too loose on finger pickup
meter

Adjust brush, page 85

Meter wheel or finger pickup has
more cells than indicated on seed
rate chart.

Charts are based on either 6 finger or 12 finger meters or
various wheel cell counts.

This manual is related to the following products: