beautypg.com

Exchanging finger sets, Remove meter cover, Remove adjustment lever – Great Plains YP4025F-1670 Operator Manual User Manual

Page 111: Remove brush block

background image

Great Plains Manufacturing, Inc.

Table of Contents

Index

Maintenance and Lubrication

107

2014-09-08

Table of Contents

Index

401-571M

Exchanging Finger Sets

Although time-consuming, corn meters may be, with care,
converted to sunflower meters, and vice-versa

a

. Starting

with factory-supplied corn meters, order quantity 16 of:

403-659A SUNFLOWER 12 FINGER CONV KIT

Refer to Figure 140

This kit contains a sunflower finger set

, Insert C

and brushless block

.

Note: Meter conversion is available only for finger pickup

meters that were originally corn meters.
Factory-supplied sunflower meters cannot be
converted to corn meters, as they lack a brush
adjustment decal, which requires a factory
alignment fixture.

Remove Meter Cover

1.

Remove the finger pickup meters from the rows
(page 81).

2.

Remove three sets of bolts and nuts securing the
cover to the meter.

Remove Adjustment Lever

Refer to Figure 141

3.

Remove the E-clip

closer to the brush block

.

4.

Withdraw the adjustment lever

. Store the removed

e-clip on it.

Note: Sunflower meters use a brushless block (installed

at step 13). The brushless block cannot be
installed with the adjustment lever present.

Remove Brush Block

5.

Remove the two screws

that secure the brush

block

, then remove the brush block.

a. Larger sunflower sizes plant with the standard Corn configuration. See “Sunflower Meter Configurations” on page 86.

Figure 140

Sunflower Conversion Kit

34530

1

2

3

1

2

3

Figure 141

Remove Adjustment Lever

34527

6

8

7

9

9

6

7

7

9

7

This manual is related to the following products: