beautypg.com

Great Plains V-300F Operator Manual User Manual

Page 62

background image

V-300, V-300F

148-057M

6/29/2006

60

Selecting the Tramline Sequence

1.

Select the

channel.

2.

Hold

to enter program mode 1.

After 3 seconds the first two digits flash, indicating the tramline
sequence currently set:-

‘SY’=Symmetric

‘AL’=Asymmetric Left

‘Ar’=Asymmetric Right

‘AS’=Special Asymmetric sequences e.g. 10 bout and 18
bout.

3.

Continue holding the

button and press and HOLD

the

button to select the required sequence.

Setting the Tramline Bout

4.

PRESS and RELEASE the

button to toggle between

the tramline sequence and tramline bout number display.
The 3

rd

and 4

th

digits flash indicating the tramline bout number

currently set.

5.

PRESS and HOLD the

button to cycle tramline the

bout from 1 to 15.

NOTE: If either asymmetric left (‘AL’) or asymmetric right (‘Ar’) se-
quences are selected, the tramline output is also switched on for
the bout following the target bout (i.e. bout 1).

If the special asymmetric sequence (‘AS’) is selected, the only op-
tions for the tramline bout number are 10 and 18.

2

4

5

2