V-300, V-300F

148-057M

6/29/2006

48

Autocal’
For maximum accuracy, perform an auto-calibration in field conditions.

1.

Set two markers at 328 feet (100 meters) apart. Choose a convenient
reference point on the tractor/implement and position this point oppo-
site the first marker.

2.

Select the

channel.

3.

HOLD

until the calibration factor is displayed.

4.

Continue holding this button and press

.

The display flashes ‘Auto’ ready for calibration.

5.

Drive the vehicle until the chosen reference point on the tractor/imple-
ment is opposite the second marker.
The instrument counts and displays the sensor pulses received over
the distance traveled
.

6.

Press the

button to complete the Autocal routine.

The calibration factor is automatically calculated and stored in
memory.

3

4

5

6

Start “Autocal”

“Autocal” Distance

Stop “Autocal”