Power requirements, Telephone line requirements, Equipment placement – ClearOne XAP TH2 User Manual

Page 9: Network requirements, Environmental requirements, Before you install

background image

5

Introduction

~ Before You Install

Technical Services Group ~ 1-800-283-5936 (USA) ~ 1-801-974-3760

Power requirements

The XAP TH2 automatically accommodates voltage requirements of 100–240VAC,

50/60Hz, 15W.

Telephone line requirements

The XAP TH2 model operates on a standard analog telephone line and connects to

the telephone system with a standard RJ-11C modular jack. If you do not have an

RJ-11C jack where you want to install your XAP TH2, call your telephone company

for installation.

The XAP TH2 can be configured to meet compliance requirements of different

countries via the G-Ware software. See page 12.

Equipment placement

The XAP TH2 models are designed for installation in a standard 19-inch equipment

rack. You can also purchase side panels for desktop placement.

Network requirements

The expansion bus (RS-485) lets you connect up to eight XAP 800/400s and 16

XAP TH2 units, where the total number of microphone inputs does not exceed 64.

The maximum distance between interconnected XAP 800/400 or PSR1212 units is

80 feet (24 meters). Insertion of a XAP TH2 must not increase the cable length

between two PSR1212s, XAP 800s and/or XAP 400s beyond 80 feet. ClearOne

recommends that category five twisted-pair (10BaseT LAN) cable be used.

Environmental requirements

The XAP TH2 can be safely operated in a room with varying temperatures between

32 °F (0 °C) and 110 °F (43 °C).

Before You Install

Warning: The country
code must be set
correctly in

G-Ware to ensure that the unit
operates properly when
connected to the telco network
and complies with the country’s
telco requirements. Changing
this code to a country other than
the intended country of
operation might cause the XAP

!